NaceCare HGB817 Owners Instructions - Page 12
Changing the Floor Tool Blades
View all NaceCare HGB817 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 12 highlights
Changing the Floor Tool Blades ! Always ensure that the machine is switched off prior to any maintenance. ! To clean the floor tool, remove securing-pin and pull-free from the holder. Rinse the floor tool assembly with clean water and refit. Periodically the floor tool blades should be examined and checked for wear and damage. The blade removal is easy. Simply start by removing the four retaining pins, turn the floor tool over and separate the blade carrier from the body. Peel away the blades from their locating lugs and examine or renew as required. Replacement is a reversal of the removal process. 1 Floor Tool Overview 2 1. Retaining pins x 4 2. Front blade (slotted) 3. Blade carrier 3 4. Rear blade 5. Floor tool main body 4 5 NOTE: The blades are designed to be reversible, thus extending their useful working life. 12 www.numatic.co.uk