Nikon 4799 F6 Instruction Manual - Page 185

Power source, Power switch, Exposure meter, Battery power, confirmation, Usable number of, exposure

Page 185 highlights

Power source Power switch Battery holder MS-41 provided (two 3V lithium batteries); optional Multi Power Battery Pack MB-40 and AA-type battery holder MS-40 available (for eight alkaline-manganese, lithium or Ni-MH batteries, or one Rechargeable Li-ion Battery EN-EL4 with optional Battery Chamber Cover BL-3); built-in backup battery for internal clock Power ON, OFF and LCD panel illuminator on position Exposure meter Auto meter shut-off 8 sec. after power turned on if no operations are performed; activated by lightly pressing shutter release button or pressing AF start button after power is turned on Battery power confirmation N for sufficient power; ˜ indicates batteries has began exhaustion; M indicates low battery power; blinking M indicates batteries are j exhausted; no indication/symbol appears when batteries are completely exhausted or improperly installed Usable number of The usable number of film roll is tested under following conditions by 36-exposure film Nikon rolls per set of Test 1 fresh batteries Camera setting: Using an AF-S VR 24-120mm f/3.5-5.6G ED lens, Vibration Reduction function on, in Continuous Servo AF with film advance mode at S and shutter speed of 1/250 sec. Autofocus operation: After lightly pressing the shutter release button for 8 sec., autofocus operation covers the full range from infinity (∞) to the closest distance and back to infinity (∞) before each shot. After the exposure meter automatically turns off, the same operation follows for the next shot. Battery Temperature 3V lithium AA-type alkaline-manganese (with MB-40) AA-type Ni-MH (with MB-40) AA-type lithium (with MB-40) Rechargeable Li-ion Battery EN-EL4 (with MB-40) At 20°C/68°F At -10°C/14°F Approx. 15 Approx. 6 Approx. 10 Approx. 1 Approx. 30 Approx. 45 Approx. 30 Approx. 35 Approx. 35 Approx. 25 Miscellaneous 185

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192

185
Miscellaneous
Power source
Battery holder MS-41 provided (two 3V lithium batteries);
optional Multi Power Battery Pack MB-40 and AA-type battery
holder MS-40 available (for eight alkaline-manganese, lithium
or Ni-MH batteries, or one Rechargeable Li-ion Battery EN-EL4
with optional Battery Chamber Cover BL-3); built-in backup
battery for internal clock
Power switch
Power ON, OFF and LCD panel illuminator on position
Exposure meter
Auto meter shut-off 8 sec. after power turned on if no
operations are performed; activated by lightly pressing shutter
release button or pressing AF start button after power is
turned on
Battery power
N
for sufficient power;
˜
indicates batteries has began
confirmation
exhaustion;
M
indicates low battery power; blinking
M
indicates batteries are j exhausted; no indication/symbol
appears when batteries are completely exhausted or
improperly installed
Usable number of
The usable number of film roll is tested under following conditions by
36-exposure film
Nikon
rolls per set of
Test 1
fresh batteries
Camera setting: Using an AF-S VR 24-120mm f/3.5-5.6G ED lens,
Vibration Reduction function on, in Continuous Servo AF with film
advance mode at S and shutter speed of 1/250 sec.
Autofocus operation: After lightly pressing the shutter release button for
8 sec., autofocus operation covers the full range from infinity (
) to the
closest distance and back to infinity (
) before each shot. After the
exposure meter automatically turns off, the same operation follows for
the next shot.
Temperature
At 20°C/68°F
At –10°C/14°F
Battery
3V lithium
Approx. 15
Approx. 6
AA-type alkaline-manganese
(with MB-40)
Approx. 10
Approx. 1
AA-type Ni-MH (with MB-40)
Approx. 30
Approx. 30
AA-type lithium (with MB-40)
Approx. 45
Approx. 35
Rechargeable Li-ion Battery EN-EL4
(with MB-40)
Approx. 35
Approx. 25