Nikon 4799 F6 Instruction Manual - Page 39

Non-CPU Nikkor

Page 39 highlights

Detailed Operation • Non-CPU Nikkor Mode Lens/accessories Focus mode Exposure mode Metering system Manual with Autofocus electronic Manual rangefinder ¡ ™ £ ¢ 3D Matrix Color Color*1 CenterWeighted, Spot*2 AI-S or AI type Nikkor, Series-E AI-modified Nikkor Non-AI-type Nikkor*5 Medical-Nikkor 120mm f/4 Reflex-Nikkor*10 PC-Nikkor*10 Teleconverter TC-16A AI-S or AI type Teleconverters Bellows Focusing Attachment PB-6 Auto Extension Rings (PK-11A, PK-12, PK-13 and PN-11) R*3 - - - - - R*14 - - - R*4 R*4 R*4 R - - - R*16 R*16 R*16 R --R R - R --R R - R - - R*6 R*7 - R - - - R*9 - R --R R - R - - R*11 R*12 - - --R R - R --R R - R - - R*17 R*7 - R R - - - - R*15 R*15 RR RR R*8 R*8 -- R R*13 R*15 R R*13 R*15 R*15 R*15 - R*13 R*13 R --R R - - RR *1 Usable by setting focal length and maximum aperture in "specifying lens data" (x 144). Accurate exposure metering cannot be obtained with some lenses even when focal length and maximum aperture are specified. Use Center-Weighted or Spot metering in this case. *2 Exposure is locked to the center focus area. *3 With TC-16A attached and maximum effective aperture of f/5.6 or faster. *4 With maximum aperture of f/5.6 or faster. *5 With modification (x 41). *6 By stop-down metering. (Release shutter while pressing depth-of-field preview button.) (x 83) *7 By stop-down metering. *8 By stop-down metering. If the aperture is slower than f/4, set "+0.5" with the "b6: Screen comp." in the Custom Setting (x 98). *9 With shutter speed set to 1/125 sec. or slower (exposure meter of the camera cannot be used). *10 Some lenses cannot be attached (x 40). *11 By stop-down metering. Exposure is determined by pre-setting lens aperture. Exposure must be determined before shifting; use AE/AF-L button before shifting. *12 By stop-down metering. Exposure is determined by pre-setting lens aperture. Exposure must be determined before shifting. *13 By stop-down metering. Set to "+0.5" in the "b6: Screen comp." in the Custom Setting (x 98). *14 With maximum aperture of f/3.5 or faster in combination with AI-S, AI or Series-E lens. However, some lenses cannot be used (x 40). *15 Exposure compensation is necessary with some lenses. See the instruction manual of the teleconverter for details. *16 With maximum effective aperture of f/5.6 or faster. *17 By stop-down metering. Exposure is determined by stopping down aperture on the bellows. Exposure must be determined before shooting. 39

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192

39
Detailed Operation
*1
Usable by setting focal length and maximum aperture in “specifying lens data” (
x
144).
Accurate exposure metering cannot be obtained with some lenses even when focal length and
maximum aperture are specified. Use Center-Weighted or Spot metering in this case.
*2
Exposure is locked to the center focus area.
*3
With TC-16A attached and maximum effective aperture of f/5.6 or faster.
*4
With maximum aperture of f/5.6 or faster.
*5
With modification (
x
41).
*6
By stop-down metering. (Release shutter while pressing depth-of-field preview button.) (
x
83)
*7
By stop-down metering.
*8
By stop-down metering. If the aperture is slower than f/4, set “+0.5” with the “b6: Screen
comp.” in the Custom Setting (
x
98).
*9
With shutter speed set to 1/125 sec. or slower (exposure meter of the camera cannot be used).
*10
Some lenses cannot be attached (
x
40).
*11
By stop-down metering. Exposure is determined by pre-setting lens aperture. Exposure must be
determined before shifting; use AE/AF-L button before shifting.
*12
By stop-down metering. Exposure is determined by pre-setting lens aperture. Exposure must be
determined before shifting.
*13
By stop-down metering. Set to “+0.5” in the “b6: Screen comp.” in the Custom Setting (
x
98).
*14
With maximum aperture of f/3.5 or faster in combination with AI-S, AI or Series-E lens. However,
some lenses cannot be used (
x
40).
*15
Exposure compensation is necessary with some lenses. See the instruction manual of the
teleconverter for details.
*16
With maximum effective aperture of f/5.6 or faster.
*17
By stop-down metering. Exposure is determined by stopping down aperture on the bellows.
Exposure must be determined before shooting.
Non-CPU Nikkor
Mode
Focus mode
Exposure mode
Metering system
Manual with
Matrix
Center-
Autofocus electronic Manual
¡
£
¢
Weighted,
Spot*
2
Lens/accessories
rangefinder
3D Color
Color*
1
AI-S or AI type Nikkor,
Series-E
R
*
3
R
*
4
R
——
R
R
R
R
R
AI-modified Nikkor
R
*
4
R
——
R
R
R
R
R
Non-AI-type Nikkor*
5
R
*
4
R
——
R
*
6
R
*
7
R
*
8
R
*
8
Medical-Nikkor
R
R
———
R
*
9
120mm f/4
Reflex-Nikkor*
10
R
——
R
R
R
R
PC-Nikkor*
10
R
——
R
*
11
R
*
12
R
*
13
R
*
13
Teleconverter TC-16A
R
*
14
——
R
R
R
*
15
R
*
15
R
*
15
AI-S or AI type
Teleconverters
R
*
16
R
——
R
R
R
*
15
R
*
15
R
*
15
Bellows Focusing
Attachment PB-6
R
*
16
R
——
R
*
17
R
*
7
R
*
13
R
*
13
Auto Extension Rings
(PK-11A, PK-12,
R
*
16
R
——
R
R
R
R
PK-13 and PN-11)