NordicTrack E 9.0 Elliptical English Manual - Page 27

Maintenance And Troubleshooting

Page 27 highlights

MAINTENANCE AND TROUBLESHOOTING Inspect and tighten all parts of the elliptical regularly. Replace any worn parts immediately. To clean the elliptical, use a damp cloth and a small amount of mild soap. IMPORTANT: To avoid damage to the console, keep liquids away from the console and keep the console out of direct sunlight. CONSOLE TROUBLESHOOTING If the console does not display your heart rate when you hold the handgrip heart rate monitor, or if the displayed heart rate appears to be too high or too low, see step 5 on page 21. HOW TO ADJUST THE DRIVE BELT If the pedals slip while you are pedaling, even while the resistance is adjusted to the highest level, the drive belt may need to be adjusted. To adjust the drive belt, first use a flat screw- driver to remove the 56 Lower Upright Cover (56). If the console does not display your heart rate Next, remove the M4 when you use the chest heart rate monitor, see x 16mm Screw (104), TROUBLESHOOTING on page 15. and then use a flat 104 screwdriver to remove 75 HOW TO CALIBRATE THE RAMP the Shield Cover (75). If the ramp is not functioning properly, the ramp may need to be calibrated. To calibrate the ramp, press and hold the Quads/Tibiales/Core button for several seconds until the test mode appears in the display. Press the Quads/Tibiales/Core button again. Then, press the 1 Step Power Ramp increase or decrease button to calibrate the ramp. The ramp will move upward and downward as it calibrates. When the ramp stops moving, the ramp is calibrated. Then, press the Quads/Tibiales/Core button repeatedly to exit the calibration mode. HOW TO GREASE THE ROLLERS Then, use a flat screwdriver to remove the Front Stabilizer Cover (8). 8 Remove all the M4 x 16mm Screws (104) from the right Disc (71). Then, gently remove the right Disc. See the EXPLODED DRAWING near the end of this manual. If the Rollers (51) squeak when moving on the Tracks (11), apply a small amount of white marine grease equally to each Roller. Spread the grease evenly around the Rollers. Pedal the elliptical until a 104 thin film of grease is distributed along the Tracks; then, 104 wipe off any excess grease. 71 104 27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

27
Inspect and tighten all parts of the elliptical regularly.
Replace any worn parts immediately.
To clean the elliptical, use a damp cloth and a small
amount of mild soap.
IMPORTANT: To avoid damage
to the console, keep liquids away from the console
and keep the console out of direct sunlight.
CONSOLE TROUBLESHOOTING
If the console does not display your heart rate when
you hold the handgrip heart rate monitor, or if the dis-
played heart rate appears to be too high or too low, see
step 5 on page 21.
If the console does not display your heart rate
when you use the chest heart rate monitor, see
TROUBLESHOOTING on page 15.
HOW TO CALIBRATE THE RAMP
If the ramp is not functioning properly, the ramp may
need to be calibrated. To calibrate the ramp, press and
hold the Quads/Tibiales/Core button for several sec-
onds until the test mode appears in the display.
Press the Quads/Tibiales/Core button again. Then,
press the 1 Step Power Ramp increase or decrease
button to calibrate the ramp. The ramp will move
upward and downward as it calibrates.
When the ramp stops moving, the ramp is calibrated.
Then, press the Quads/Tibiales/Core button repeatedly
to exit the calibration mode.
HOW TO GREASE THE ROLLERS
See the EXPLODED DRAWING near the end of this
manual. If the Rollers (51) squeak when moving on
the Tracks (11), apply a small amount of white marine
grease equally to each Roller. Spread the grease
evenly around the Rollers. Pedal the elliptical until a
thin
lm of grease is distributed along the Tracks; then,
wipe off any excess grease.
HOW TO ADJUST THE DRIVE BELT
If the pedals slip while you are pedaling, even while
the resistance is adjusted to the highest level, the drive
belt may need to be adjusted.
To adjust the drive belt,
first use a flat screw-
driver to remove the
Lower Upright Cover
(56).
Next, remove the M4
x 16mm Screw (104),
and then use a flat
screwdriver to remove
the Shield Cover (75).
Then, use a flat screw-
driver to remove the
Front Stabilizer Cover
(8).
Remove all the M4 x 16mm Screws (104) from the
right Disc (71). Then, gently remove the right Disc.
MAINTENANCE AND TROUBLESHOOTING
56
104
104
8
71
104
104
75