MAINTENANCE AND TROUBLESHOOTING Inspect and tighten all parts of the exercise bike regularly. Replace any worn parts immediately. To clean the exercise bike, use a damp cloth and a small amount of mild soap. IMPORTANT: To avoid damage to the console, keep liquids away from the console and keep the console out of direct sunlight. CONSOLE TROUBLESHOOTING If lines appear in the console display, see step 3 on page 23 and adjust the contrast level of the display. If the console does not display your heart rate when you use the handgrip heart rate monitor, see step 5 on page 18. HOW TO ADJUST THE REED SWITCH If the console does not display correct feedback, the reed switch should be adjusted. To adjust the reed switch, first unplug the power adapter. Next, using a flat screwdriver, carefully remove the Shield Cover (26) from the Left and Right Shields (37, 58). 26 37, 58 Locate the Reed Switch (64). Loosen, but do not remove, the M4 x 19mm Screw (65). 35 54 65 64 Next, rotate the Left Crank Arm (35) until a Magnet (54) is aligned with the Reed Switch (64). Slide the Reed Switch slightly toward or away from the Magnet. Then, retighten the M4 x 19mm Screw (65). Plug in the power adapter and rotate the Left Crank Arm (35) for a moment. Repeat these actions until the console displays correct feedback. When the reed switch is correctly adjusted, reattach the shield cover. 25

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

25
Inspect and tighten all parts of the exercise bike regu-
larly. Replace any worn parts immediately.
To clean the exercise bike, use a damp cloth and a
small amount of mild soap.
IMPORTANT: To avoid
damage to the console, keep liquids away from
the console and keep the console out of direct
sunlight.
CONSOLE TROUBLESHOOTING
If lines appear in the console display, see step 3 on
page 23 and adjust the contrast level of the display.
If the console does not display your heart rate when
you use the handgrip heart rate monitor, see step 5 on
page 18.
HOW TO ADJUST THE REED SWITCH
If the console does not display correct feedback, the
reed switch should be adjusted.
To adjust the
reed switch,
first unplug the
power adapter.
Next, using a
flat screwdriver,
carefully remove
the Shield Cover
(26) from the
Left and Right
Shields (37, 58).
Locate the Reed Switch (64). Loosen, but do not
remove, the M4 x 19mm Screw (65).
Next, rotate the Left Crank Arm (35) until a Magnet (54)
is aligned with the Reed Switch (64). Slide the Reed
Switch slightly toward or away from the Magnet. Then,
retighten the M4 x 19mm Screw (65).
Plug in the power adapter and rotate the Left Crank
Arm (35) for a moment. Repeat these actions until the
console displays correct feedback.
When the reed switch is correctly adjusted, reattach
the shield cover.
MAINTENANCE AND TROUBLESHOOTING
26
37, 58
65
35
64
54