Oki C942 C911dn/C931dn/C931DP/C941dn/C941DP/C942 Troubleshooting Guide - Engli - Page 90
and remove the belt unit., Hold the handle and pull out the belt
View all Oki C942 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 90 highlights
Troubleshooting Device Maintenance 8 Hold the handle and pull out the belt unit, hold the left-right label part (blue) 1 and remove the belt unit. zz Never place the belt units that have you removed in a vertical direction. 2 6.6 kg 9 Gently wipe the surface of LED head with a soft tissue paper. Maintenance Index Note zz Do not touch the belt surface or damage the belt. Note zz Agents such as methyl alcohol and thinner will damage the LED head, so please do not use them. zz Removing the belt unit will expose all image drums to light. For preventing the optical deterioration of image drums, do not leave them as it is for more than 5 minutes after removing the belt unit. When leaving for more than 5 minutes, close the front cover, or remove all image drums and store them in a safe place where they are not directly exposed to sunlight or fluorescent light. zz Ensure that waste toner does not spill when removing the belt unit. - 90 -