Panasonic 16 000lm / 1080p / 3-Chip DLP™ Projector Operating Manual - Page 190

Self-diagnosis display

Page 190 highlights

Chapter 5 Maintenance - Self-diagnosis display Self-diagnosis display There is a self-diagnosis display on the side of the projector. Self-diagnosis display will automatically display the value of the input supply voltage, or details of errors or warnings when they occur. (x page 28) The following list shows the alphanumeric symbol that is displayed when an error or a warning has occurred and its details. The input supply voltage is displayed only with the numeric value. Error/warning display U04 U11 U12 Details Air filter clogging Intake temperature warning Optical module temperature warning U13 Exhaust air temperature warning U14 Low temperature warning U21 Intake temperature error U22 Optical module temperature error U23 Exhaust air temperature error U24 U30 U31 U32 U33 U35*2 U41 U42 U43 U44 U51 U52 U53 U54 U61 U62 U63 U64 U71 U72 U73 U74 U76 U78 U81 Low temperature error Installation angle error Portrait installation angle error Used lamp unit error Used lamp unit mix-up error Non-compatible lamp warning Lamp 1 runtime warning Lamp 2 runtime warning Lamp 3 runtime warning Lamp 4 runtime warning Lamp 1 error Lamp 2 error Lamp 3 error Lamp 4 error Lamp 1 runtime has exceeded 3 000 hours*3 Lamp 2 runtime has exceeded 3 000 hours*3 Lamp 3 runtime has exceeded 3 000 hours*3 Lamp 4 runtime has exceeded 3 000 hours*3 Lamp 1 not installed Lamp 2 not installed Lamp 3 not installed Lamp 4 not installed Air filter unit not installed Clog sensor error Low AC voltage warning (below 170 V) Measure ff Clean the air filter unit. ff The operating environment temperature is too high. Use the projector in an appropriate operating environment temperature*1. ff The operating environment temperature is too high, or the air exhaust port may be blocked. Use the projector in an appropriate operating environment temperature*1. Or remove any objects that are blocking the air exhaust port. ff The operating environment temperature is too low. Use the projector in an appropriate operating environment temperature*1. ff The operating environment temperature is too high. Use the projector in an appropriate operating environment temperature*1. ff The operating environment temperature is too high, or the air exhaust port may be blocked. Use the projector in an appropriate operating environment temperature*1. Or remove any objects that are blocking the air exhaust port. ff The operating environment temperature is too low. Use the projector in an appropriate operating environment temperature*1. ff Use the projector at an angle not exceeding ±15° from the horizontal plane. ff Install the projector with the connecting terminals down. ff To install in portrait, use the Replacement lamp unit (for portrait mode). ff A different type of lamp unit is attached. Check the model number displayed on the lamp unit and use a lamp unit with the same model number. ff The lamp unit for portrait mode is attached. Replace the lamp unit with one compatible with the projector. ff It will reach the lamp replacement time. Replace the lamp unit. ff Failed to light the lamp. Turn on the power again after the lamp is cooled. If the lamp still does not light, consult your dealer. ff It has reached the lamp replacement time. Replace the lamp unit. ff Attach the lamp unit. ff Attach the air filter unit. ff Clean or replace the air filter unit. (x page 181) ff The input supply voltage is low. Use electric wiring that can sufficiently withstand the power consumption of the projector. 190 - ENGLISH

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223

Chapter 5
Maintenance — Self-diagnosis display
190 - ENGLISH
Self-diagnosis display
There is a self-diagnosis display on the side of the projector. Self-diagnosis display will automatically display the
value of the input supply voltage, or details of errors or warnings when they occur. (
x
page 28)
The following list shows the alphanumeric symbol that is displayed when an error or a warning has occurred and
its details. The input supply voltage is displayed only with the numeric value.
Error/warning display
Details
Measure
U04
Air filter clogging
f
Clean the air filter unit.
U11
Intake temperature warning
f
The operating environment temperature is too
high. Use the projector in an appropriate operating
environment temperature
*1
.
U12
Optical module temperature warning
U13
Exhaust air temperature warning
f
The operating environment temperature is too
high, or the air exhaust port may be blocked.
Use the projector in an appropriate operating
environment temperature
*1
. Or remove any objects
that are blocking the air exhaust port.
U14
Low temperature warning
f
The operating environment temperature is too
low. Use the projector in an appropriate operating
environment temperature
*1
.
U21
Intake temperature error
f
The operating environment temperature is too
high. Use the projector in an appropriate operating
environment temperature
*1
.
U22
Optical module temperature error
U23
Exhaust air temperature error
f
The operating environment temperature is too
high, or the air exhaust port may be blocked.
Use the projector in an appropriate operating
environment temperature
*1
. Or remove any objects
that are blocking the air exhaust port.
U24
Low temperature error
f
The operating environment temperature is too
low. Use the projector in an appropriate operating
environment temperature
*1
.
U30
Installation angle error
f
Use the projector at an angle not exceeding ±15°
from the horizontal plane.
U31
Portrait installation angle error
f
Install the projector with the connecting terminals
down.
U32
Used lamp unit error
f
To install in portrait, use the Replacement lamp unit
(for portrait mode).
U33
Used lamp unit mix-up error
f
A different type of lamp unit is attached. Check the
model number displayed on the lamp unit and use
a lamp unit with the same model number.
U35
*2
Non-compatible lamp warning
f
The lamp unit for portrait mode is attached.
Replace the lamp unit with one compatible with the
projector.
U41
Lamp 1 runtime warning
f
It will reach the lamp replacement time. Replace
the lamp unit.
U42
Lamp 2 runtime warning
U43
Lamp 3 runtime warning
U44
Lamp 4 runtime warning
U51
Lamp 1 error
f
Failed to light the lamp. Turn on the power again
after the lamp is cooled. If the lamp still does not
light, consult your dealer.
U52
Lamp 2 error
U53
Lamp 3 error
U54
Lamp 4 error
U61
Lamp 1 runtime has exceeded 3 000 hours
*3
f
It has reached the lamp replacement time. Replace
the lamp unit.
U62
Lamp 2 runtime has exceeded 3 000 hours
*3
U63
Lamp 3 runtime has exceeded 3 000 hours
*3
U64
Lamp 4 runtime has exceeded 3 000 hours
*3
U71
Lamp 1 not installed
f
Attach the lamp unit.
U72
Lamp 2 not installed
U73
Lamp 3 not installed
U74
Lamp 4 not installed
U76
Air filter unit not installed
f
Attach the air filter unit.
U78
Clog sensor error
f
Clean or replace the air filter unit. (
x
page 181)
U81
Low AC voltage warning (below 170 V)
f
The input supply voltage is low. Use electric
wiring that can sufficiently withstand the power