Panasonic FV-05-11VK1 Installation Instructions - Page 10

Installation Retrofit, Installation New Construction Continued

Page 10 highlights

INSTALLATION (NEW CONSTRUCTION) CONTINUED 13. Adjust Pick-A-Flow switch; if used, adjust the FV-VS15VK1 Multi-Speed module. (Fig.10) Refer to indication on page 6. Ceiling 14. Insert the other mounting spring into the slot as shown and mount grille to fan body. (Fig.11) CAUTION Mount grille carefully so that lead wire is not pinched. Ceiling Gloves Grille Grille Fig.10 Mounting spring Fig.11 INSTALLATION (RETROFIT) WARNING Conduit Circular duct Unit: inches (mm) Joist 10 7/8 (275) Disconnect power source before working on unit. 1. Remove the existing fan and cut ceiling openning. Secure the Flex-Z FastTM bracket to joists by drilling 4 tapping screws (ST4.2x20) which have been fixed on it. Existing ductwork and wiring left in place. (Fig.12) 2. Follow the step 1, 4, 5 on page 8 and step 7 on page 9. (Before connect the circular duct to the adaptor, should pull down the circular duct from the ceiling) 3. Install the adaptor to Flex-Z FastTM bracket by using 2 self-drilling screws. (Fig.13) 4. Secure the fan body to Flex-Z FastTM bracket by using 2 self-drilling screws, plug connector to receptacle and secure the fan body to adaptor by using machine screw (M4X6). (Fig.14) 4 Tapping screws (ST4.2x20) Ceiling (already existed) 10 7/8 (275) Fig.12 Circular duct Conduit Mastic or approved foil tape Joist Knock-out hole Junction box cover Ceiling 2 Self-drilling screws Fig.13 Joist CAUTION Secure machine screw (M4X6) to the suitable hole and not touch the Flex-Z FastTM bracket. Please fix the screw carefully to avoid screw slip teeth. 5. Follow the step 10 to 14 on page 9 to 10. Ceiling Machine screw (M4X6) Flange 2 Self-drilling screws (Fix the flange and Flex-Z FastTM bracket through the ceiling) Fig.14 10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

10
INSTALLATION (RETROFIT)
INSTALLATION (NEW CONSTRUCTION) CONTINUED
CAUTION
Fig.10
Fig.11
Grille
Grille
Ceiling
Mounting
spring
14. Insert the other mounting spring into the slot as
shown and mount grille to fan body. (Fig.11)
Mount grille carefully so that lead wire is
not pinched.
Ceiling
Gloves
13. Adjust Pick-A-Flow switch; if used, adjust the
FV-VS15VK1 Multi-Speed module. (Fig.10)
Refer to indication on page 6.
Ceiling
Flange
Joist
Machine screw (M4X6)
2 Self-drilling screws (Fix the
TM
flange and Flex-Z Fast
bracket through the ceiling)
Fig.13
Mastic or
approved
foil tape
2 Self-drilling screws
Ceiling
Joist
Knock-out
hole
Junction box
cover
Conduit
Circular duct
Fig.14
WARNING
1. Remove the existing fan and cut ceiling openning.
2. Follow the step 1, 4, 5 on page 8 and step 7 on
page 9. (Before connect the circular duct to the
adaptor, should pull down the circular duct from
the ceiling)
Disconnect power source before working
on unit.
5. Follow the step 10 to 14 on page 9 to 10.
TM
Secure the Flex-Z Fast
bracket to joists by drilling
4 tapping screws (ST4.2x20) which have been fixed
on it. Existing ductwork and wiring left in place.
(Fig.12)
TM
3. Install the adaptor to Flex-Z Fast
bracket by
using 2 self-drilling screws. (Fig.13)
TM
4. Secure the fan body to Flex-Z Fast
bracket by
using 2 self-drilling screws, plug connector to
receptacle and secure the fan body to adaptor
by using machine screw (M4X6). (Fig.14)
Secure machine screw (M4X6) to the suitable
TM
hole and not touch the Flex-Z Fast
bracket.
Please fix the screw carefully to avoid screw
slip teeth.
CAUTION
Fig.12
10 7/8
(275)
10 7/8
(275)
Ceiling (already existed)
Conduit
Circular duct
Joist
4 Tapping
screws (ST4.2x20)
Unit: inches (mm)