Panasonic SU-R1000 Owners Manual - Page 27

Coax1, Coax2, Opt1, Opt2, Pc1 Or

Page 27 highlights

Disconnect PHONES • When the headphones are connected, measuring the output signal of the amplifier (LAPC) will not start. • Disconnect the headphones. • If you connect headphones during amplifier signal measurement or amplifier output correction, it will be cancelled. ( 22) "F " (" " stands for a number.) • An abnormality has occurred. (If this unit detects an abnormality, the protection circuit is activated, and the power may be turned off automatically.) - Is the volume extremely high? Or is this unit placed in an extremely hot place? Wait a few seconds and then turn the unit on again. (The protection circuit will be deactivated.) Load Fail • The firmware cannot be found on the USB flash memory. • Download the latest firmware on the USB flash memory and try again. ( 23) Measurement Fail • The measurement or processing of "Cartridge Optimiser" fails. Make the following checks. "High Level": The output signal is so noisy or the output signal level of turntable is too high. Remove the dust from the record. Confirm the setting of "Gain" and adjust the input level of this unit ( 16). Check if "MM/MC" setting of this unit matches the cartridge type of the turntable or not ( 16). "Low Level": The record is not played back, or the output signal level of turntable is too low. Confirm the turntable is connected correctly and the record is played back properly ( 16). Confirm the setting of "Gain" and adjust the input level of this unit ( 16). Check if "MM/MC" setting of this unit matches the cartridge type of the turntable or not ( 16). "Low Quality": The output signal of turntable is so noisy. Remove the dust from the record. Or play another track. If the problem still persists, consult your dealer. "Speed Mismatch": Rotation per minute (RPM) is incorrect. Adjust the rotation of turntable and play back in correct RPM. "System Error": It may be system error. Consult your dealer. No Device • USB flash memory with new firmware is not connected. Connect the USB flash memory with new firmware. ( 23) Not Measured • Measuring the output signal for the output correction function (LAPC) has not been done yet. • Measure the output signal. ( 22) Not Valid • The function you have tried to use is not available with the current settings. Check the steps and settings. • The current input source is different from the one in "Cartridge Optimiser" setting. Switch the input source correctly. ( 16) • [MUTE] is not valid while the measurement of "Cartridge Optimiser". Adjust the volume. PHONES Connected • The headphones are connected. • Sound is not output from headphones jack and speaker output terminals when the headphones are connected and "MAIN IN" is selected as input source of this unit. ( 18) "Remote " (" " stands for a number.) • The remote control and this unit are using different modes. Change the mode on the remote control. ( 11) Unlocked • "COAX1", "COAX2", "OPT1", "OPT2", "PC1" or "PC2" is selected, but no device is connected. Check the connection with the device. ( 13, 14) • The sampling frequency components, etc. of the audio signals are not input correctly. - About supported format, refer to "Format support". ( 28) USB Over Current USB device is drawing too much power. • Disconnect the USB device and connect it again. ( 23) • Turn the unit to standby and on again. VOLUME OK (" " stands for a number.) • When the input source is switched from "MAIN IN", the volume level after switching the input source is displayed. • Confirm and adjust the volume before pressing [OK]. Troubleshooting (27) 27 English

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

27
English
Troubleshooting
(27)
Disconnect PHONES
When the headphones are connected,
measuring the output signal of the amplifier
(LAPC) will not start.
Disconnect the headphones.
If you connect headphones during amplifier
signal measurement or amplifier output
correction, it will be cancelled. (
22)
“F
” (“
” stands for a number.)
An abnormality has occurred. (If this unit
detects an abnormality, the protection circuit
is activated, and the power may be turned off
automatically.)
-
Is the volume extremely high? Or is this unit
placed in an extremely hot place?
Wait a few seconds and then turn the unit
on again. (The protection circuit will be
deactivated.)
Load Fail
The firmware cannot be found on the USB flash
memory.
Download the latest firmware on the USB flash
memory and try again. (
23)
Measurement Fail
The measurement or processing of “Cartridge
Optimiser” fails. Make the following checks.
“High Level”:
The output signal is so noisy or the output
signal level of turntable is too high. Remove the
dust from the record. Confirm the setting of
“Gain” and adjust the input level of this unit
(
16).
Check if “MM/MC” setting of this unit matches
the cartridge type of the turntable or not
(
16).
“Low Level”:
The record is not played back, or the output
signal level of turntable is too low. Confirm the
turntable is connected correctly and the record
is played back properly (
16).
Confirm the setting of “Gain” and adjust the
input level of this unit (
16).
Check if “MM/MC” setting of this unit matches
the cartridge type of the turntable or not
(
16).
“Low Quality”:
The output signal of turntable is so noisy.
Remove the dust from the record. Or play
another track. If the problem still persists,
consult your dealer.
“Speed Mismatch”:
Rotation per minute (RPM) is incorrect. Adjust
the rotation of turntable and play back in
correct RPM.
“System Error”:
It may be system error. Consult your dealer.
No Device
USB flash memory with new firmware is not
connected.
Connect the USB flash memory with new
firmware. (
23)
Not Measured
Measuring the output signal for the output
correction function (LAPC) has not been done
yet.
Measure the output signal. (
22)
Not Valid
The function you have tried to use is not
available with the current settings. Check the
steps and settings.
The current input source is different from the
one in “Cartridge Optimiser” setting. Switch the
input source correctly. (
16)
[MUTE] is not valid while the measurement of
“Cartridge Optimiser”. Adjust the volume.
PHONES Connected
The headphones are connected.
Sound is not output from headphones jack and
speaker output terminals when the headphones
are connected and “MAIN IN” is selected as
input source of this unit. (
18)
“Remote
” (“
” stands for a number.)
The remote control and this unit are using
different modes.
Change the mode on the remote control. (
11)
Unlocked
“COAX1”, “COAX2”, “OPT1”, “OPT2”, “PC1” or
“PC2” is selected, but no device is connected.
Check the connection with the device.
(
13, 14)
The sampling frequency components, etc. of
the audio signals are not input correctly.
-
About supported format, refer to “Format
support”. (
28)
USB Over Current
USB device is drawing too much power.
Disconnect the USB device and connect it
again. (
23)
Turn the unit to standby and on again.
VOLUME
OK (“
” stands for a number.)
When the input source is switched from “MAIN
IN”, the volume level after switching the input
source is displayed.
Confirm and adjust the volume before pressing
[OK].