Panasonic WV-CW594 Installation Guide - Page 15
RS485 Communication Parameters DIP Switch 1
View all Panasonic WV-CW594 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
■ RS485 Communication Parameters (DIP Switch 1) Configuring DIP Switch 1 as shown below resets communication parameters to their factory default settings. You can then change the settings as desired. DIP Switch 1 ON 12345678 ON 12345678 ON 12345678 ON 12345678 ON 12345678 Setting Description This setting resets communication parameters to the factory default settings. BAUD RATE : 19 200 bit/s, DATA BIT : 8 bit, PARITY CHECK : NONE, STOP BIT : 1 bit BAUD RATE : 9 600 bit/s, DATA BIT : 8 bit, PARITY CHECK : NONE, STOP BIT : 1 bit BAUD RATE : 4 800 bit/s, DATA BIT : 8 bit, PARITY CHECK : NONE, STOP BIT : 1 bit BAUD RATE : 2 400 bit/s, DATA BIT : 8 bit, PARITY CHECK : NONE, STOP BIT : 1 bit Perform the following steps to use this setting. (1) Turn off the camera and use DIP Switch 1 to configure RS485 communication parameters as shown above. (2) Turn on the camera. This applies the setting you configured in step (1). (3) Turn off the camera, use DIP Switch 1 to set the unit number (☞ pages 13 and 14), and then turn the camera back on again. 15