Panasonic WV-CW594 Installation Guide - Page 15

RS485 Communication Parameters DIP Switch 1

Page 15 highlights

■ RS485 Communication Parameters (DIP Switch 1) Configuring DIP Switch 1 as shown below resets communication parameters to their factory default settings. You can then change the settings as desired. DIP Switch 1 ON 12345678 ON 12345678 ON 12345678 ON 12345678 ON 12345678 Setting Description This setting resets communication parameters to the factory default settings. BAUD RATE : 19 200 bit/s, DATA BIT : 8 bit, PARITY CHECK : NONE, STOP BIT : 1 bit BAUD RATE : 9 600 bit/s, DATA BIT : 8 bit, PARITY CHECK : NONE, STOP BIT : 1 bit BAUD RATE : 4 800 bit/s, DATA BIT : 8 bit, PARITY CHECK : NONE, STOP BIT : 1 bit BAUD RATE : 2 400 bit/s, DATA BIT : 8 bit, PARITY CHECK : NONE, STOP BIT : 1 bit Perform the following steps to use this setting. (1) Turn off the camera and use DIP Switch 1 to configure RS485 communication parameters as shown above. (2) Turn on the camera. This applies the setting you configured in step (1). (3) Turn off the camera, use DIP Switch 1 to set the unit number (☞ pages 13 and 14), and then turn the camera back on again. 15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

15
RS485 Communication Parameters (DIP Switch 1)
Configuring DIP Switch 1 as shown below resets communication parameters to their factory default settings. You can
then change the settings as desired.
1
2
3
4
ON
5
6
7
8
DIP Switch 1
Setting Description
1
2
3
4
ON
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
ON
5
6
7
8
1
2
3
4
ON
5
6
7
8
This setting resets communication parameters to the factory default settings.
BAUD RATE : 19 200 bit/s, DATA BIT : 8 bit, PARITY CHECK : NONE, STOP BIT : 1 bit
BAUD RATE : 9 600 bit/s, DATA BIT : 8 bit, PARITY CHECK : NONE, STOP BIT : 1 bit
BAUD RATE : 4 800 bit/s, DATA BIT : 8 bit, PARITY CHECK : NONE, STOP BIT : 1 bit
BAUD RATE : 2 400 bit/s, DATA BIT : 8 bit, PARITY CHECK : NONE, STOP BIT : 1 bit
ON
Perform the following steps to use this setting.
(1) Turn off the camera and use DIP Switch 1 to configure RS485 communication parameters as shown above.
(2) Turn on the camera.
This applies the setting you configured in step (1).
(3) Turn off the camera, use DIP Switch 1 to set the unit number (
pages 13 and 14), and then turn the camera
back on again.