Panasonic WV-CW594 Installation Guide - Page 21
Alarm In/Out Ratings, Alarm In, Alarm Out, Important
View all Panasonic WV-CW594 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 21 highlights
Alarm In/Out Ratings Alarm In : 5 V DC pull-up input. Drive capacity of at lease 0.2 mA required. OFF : 4 V to 5 V DC, or open ON : 1 V DC or less, or short Alarm Out : O pen collector output. 16 V DC, maximum drive current: 100 mA OFF : Open ON : 100 mA or less Note: • Do not turn off camera power within 30 seconds after turning it on. Doing so can cause pan, tilt, zoom, or focus to go out of position. • 24 V AC Power Supply Connection Recommended wire gauge sizes for 24 V AC line Copper wire size #24 #22 #20 #18 (AWG) (0.22mm2) (0.33mm2) (0.52mm2) (0.83mm2) Length of cable (approx.) (m) 20 30 45 75 Important: • The power supply of 24 V AC shall be insulated against 220 to 240 V AC. 21
21
Alarm In/Out Ratings
Alarm In
:
5 V DC pull-up input. Drive capacity of at
lease 0.2 mA required.
OFF :
4 V to 5 V DC, or open
ON :
1 V DC or less, or short
Alarm Out :
Open collector output. 16 V DC,
maximum drive current: 100 mA
OFF :
Open
ON :
100 mA or less
Note:
• Do not turn off camera power within 30 seconds
after turning it on. Doing so can cause pan, tilt,
zoom, or focus to go out of position.
• 24 V AC Power Supply Connection
Recommended wire gauge sizes for 24 V AC line
#24
(0.22mm
2
)
Copper wire size
(AWG)
Length of
cable (approx.)
#22
(0.33mm
2
)
#20
(0.52mm
2
)
#18
(0.83mm
2
)
(m)
20
30
45
75
Important:
• The power supply of 24 V AC shall be insulated
against 220 to 240 V AC.