Pioneer CT-W404R Operating Instructions - Page 17

Pioneer CT-W404R Manual

Page 17 highlights

TROUBLESHOOTING Symptom POOR SOUND QUALITY Unstable sound. or interrupted I Cause I Remedy The head, pinch rollers and capstans are dirty. The tape is not uniformly wound. e Clean (see page 4). Completely fast-forward or rewind the tape. No high frequencies. e A tape recorded without Dolby NR is being played back with DOLBY NR switch in the B orC position. The head is dirty. A Dolby NR-encoded tape is being played back with DOLBY NR switch in the OFF position. Set DOLBY NR switch to OFF. Clean the head (see page 4). Set DOLBY NR switch to the same position used for recording. High frequencies are emphasized. Sound from previous recordings remains when rerecording a tape. The sound is distorted. • The head is dirty. • Clean the head (see page 4). • • • Recording level is too high. The recorded signal itself is distorted. The head is dirty. High noise tape is being used. Incomplete insertion of a connection contact. Recording level is too low. The head is dirty. The head is magnetized. • • a Turn REC LEVEL control down when recording (see page 13). Replace the cassette. Clean the head Isee page 41. Replace the cassette. Check connections (see page 6). Turn REC LEVEL control up when recording page 13). Clean the head (see page 4). Demagnetize with a head demagnetizer. (see Too much noise. cord, poor OTHERS The music search function does not work. Cannot use the remote control system. CD • DECK SYNCHRO is disabled. (CT-W504R only) • • The components are not connected properly. The cassette erasure prevention tabs are broken. • • Connect them properly (see page 6). Replace the cassette with one whose tabs are intact. Replace the tape with a longer one. Change the disc and press the CD SYNC button again. • • Blanks between selections are less than 4 seconds long. The control cord is not connected. • Connect the control cord (see page 6). • Use a tape with blanks more than 4 seconds long. The CD SYNC indicator is off during CD ° DECK SYNCHRO recording. (CT-W504R only) • • The tape ran out during the CD ° DECK SYNCHRO mode. After the deck entered recording standby mode, more than 1 minute elapsed before the CD player resumed playback. e Abnormal functioning of this unit may be caused by lightning, static electricity, or other external interference. To restore normal operation, turn the power off and then on again, or unplug the AC power cord and then plug it in again. POWER-CORD CAUTION Handle the power cord by the plug. Do not pull out the plug by tugging the cord and never touch the power cord when your hands are wet as this could cause a short circuit or electric shock. Do not place the unit, a piece of furniture, etc., on the power cord, or pinch the cords. Never make a knot in the cord or tie it with other cords. The power shoud be routed in such a way that they are not likely to be stepped on. A damaged power cord can cause fire or give you an electrical shock.Check the power cord once in a while. When you find it damaged, ask your nearest PIONEER authorized service center or your dealer for a replacement. 17 En

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

TROUBLESHOOTING
Symptom
POOR
SOUND
QUALITY
Unstable
or
interrupted
sound.
No high
frequencies.
High
frequencies
are
emphasized.
Sound
from
previous
recordings
remains
when
rerecording
a tape.
The
sound
is distorted.
Too much
noise.
I
e
e
Cause
The head,
pinch rollers
and
capstans
are
dirty.
The tape is not uniformly
wound.
A tape recorded
without
Dolby
NR is being
played
back with
DOLBY
NR switch
in the B orC position.
The head
is dirty.
A Dolby NR-encoded
tape is being
played back with
DOLBY
NR switch
in the OFF position.
The
head
is dirty.
Recording
level is too high.
The
recorded
signal itself
is distorted.
The
head
is dirty.
High noise tape is being
used.
Incomplete
insertion
of
a connection
cord,
poor
contact.
Recording
level
is too low.
The head
is dirty.
The
head
is magnetized.
I
Remedy
Clean
(see page 4).
Completely
fast-forward
or rewind
the tape.
Set DOLBY
NR
switch
to
OFF.
Clean the head
(see page
4).
Set DOLBY
NR switch
to the same
position
used
for recording.
Clean the head
(see page
4).
Turn
REC LEVEL control
down
when
recording
(see page 13).
Replace the cassette.
a
Clean the head
Isee page
41.
Replace the cassette.
Check
connections
(see page 6).
Turn
REC LEVEL
control
up when
recording
(see
page 13).
Clean
the head
(see page
4).
Demagnetize
with
a head demagnetizer.
OTHERS
The
music
search function
Blanks
between
selections
are
less than 4 seconds
Use
a
tape with
blanks
more
than 4 seconds long.
does
not
work.
long.
Cannot use
the
remote
The control
cord
is
not connected.
Connect
the control
cord (see page 6).
control
system.
CD • DECK SYNCHRO
is
The components
are not connected
properly.
disabled.
(CT-W504R
only)
The cassette
erasure
prevention
tabs
are broken.
The CD SYNC indicator
is
off during
CD ° DECK
SYNCHRO
recording.
(CT-W504R
only)
The tape
ran out during
the
CD
°
DECK SYNCHRO
mode.
After
the
deck
entered
recording
standby
mode,
more
than
1 minute
elapsed
before
the
CD player
resumed
playback.
e
Connect
them
properly
(see page 6).
Replace
the cassette
with
one whose
tabs
are in-
tact.
Replace the tape with
a longer
one.
Change
the disc
and press
the
CD SYNC
button
again.
Abnormal
functioning
of this
unit
may
be
caused
by lightning,
static
electricity,
or other
external
interference.
To restore
normal
operation,
turn the power
off and then on again, or unplug
the AC power
cord and
then plug it in again.
POWER-CORD
CAUTION
Handle the power
cord by the plug.
Do not pull out the plug
by tugging
the cord and never touch
the power
cord when
your hands
are wet
as
this could cause a short circuit
or electric
shock.
Do not place the unit,
a piece of furniture,
etc.,
on the power
cord, or pinch the cords.
Never
make
a knot
in the cord or tie it with
other
cords.
The power
shoud
be
routed
in
such a
way
that they
are not likely
to
be stepped
on.
A dam-
aged power
cord can cause fire or give you an electrical
shock.Check
the
power
cord once
in a while.
When
you
find
it damaged,
ask your
nearest
PIONEER
authorized
service
center
or your
dealer
for
a re-
placement.
17
<RRB1155>
En