Pioneer PDA-5004 Operating Instructions - Page 29

Automatic power-off, POWER MANAGEMENT

Page 29 highlights

English Operation Automatic power-off (POWER MANAGEMENT) The plasma display is equipped with [POWER MANAGEMENT] and [AUTO POWER OFF] functions; when set, the function automatically switches the unit to either standby mode or power off mode whenever a sync signal is not detected (a warning message is displayed on the screen before the functions operate). Notes ÷ [POWER MANAGEMENT] settings are supported only when a computer signal is input to INPUT 1 or INPUT 5 (PDA-5003 only), or when INPUT2 is selected. ÷ The auto-power-off function can be used only in those cases other than the inputs used in the preceding item. ÷ Always turn off the plasma display's main power switch when not using the display for extended periods of time. INPUT MENU INPUT 2/3 SET MENU 2/3 SET Display operating panel Remote control unit 1 Press the MENU button to display the menu screen. MENU PICTURE SCREEN CONTRAST : BRIGHTNESS : R.LEVEL : G.LEVEL : B.LEVEL : H.ENHANCE : V. E N H A N C E : SETUP 0 0 0 0 0 0 0 INPUT1 OPTION PICTURE RESET 2 Use the 2/3 buttons to select [SETUP]. [When computer signal is input to INPUT1 or INPUT5 (PDA-5003 only), or when INPUT2 is used] MENU INPUT1 PICTURE SCREEN SETUP OPTION POWER MANAGEMENT CLAMP POSITION SIGNAL FORMAT : OFF : AUTO : VGA [In all other cases] MENU PICTURE SCREEN AUTO POWER OFF COLOR TEMP. DNR MPEG NR CTI PURECINEMA COLOR SYSTEM INPUT3 SETUP OPTION : DISABLE : MIDDLE : MIDDLE : LOW : ON : OFF : AUTO SET CHANGE MENU EXIT 3 Press the SET button to confirm selection of the [POWER MANAGEMENT] or [AUTO POWER OFF]. The factory default setting is [OFF/DISABLE]. Each time the button is pressed, the setting alternates as follows: 3 OFF/DISABLE ON/ENABLE 2 ÷ OFF/DISABLE..... The display will continue in operating mode, regardless of the presence/absence of an input sync signal. ÷ POWER MANAGEMENT: ON..... If a sync signal is not detected, a warning message is first displayed for 8 seconds, after which the display automatically enters the standby mode, and the ON indicator flashes green. If a sync signal (*1) is input again later, the plasma display automatically returns to normal operating mode. *1 Except when input signal is G ON SYNC or composite SYNC. ÷ AUTO POWER OFF: ENABLE..... If no sync signal is detected for 8 minutes or more, a warning message will be displayed for 30 seconds, after which the display's power will switch to power off mode. 4 When the setup is finished, press the MENU button to exit the menu screen. Note The [POWER MANAGEMENT] and [AUTO POWER OFF] functions must be set individually for each input (INPUT1 to INPUT5). To return to operating mode: ÷ To return to normal operation from the [POWER MANAGEMENT] function's standby mode, either operate your computer, or press the INPUT button on the plasma display or remote control unit. ÷ To return to normal operation from the [AUTO POWER OFF] function's power off condition, press the STANDBY/ ON button on the plasma display or on the remote control unit. Operation 26 En

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99

26
En
English
Operation
Automatic power-off
(POWER MANAGEMENT)
The plasma display is equipped with [POWER
MANAGEMENT] and [AUTO POWER OFF] functions;
when set, the function automatically switches the unit to
either standby mode or power off mode whenever a sync
signal is not detected (a warning message is displayed on
the screen before the functions operate).
Notes
÷
[POWER MANAGEMENT] settings are supported only when a
computer signal is input to INPUT 1 or INPUT 5 (PDA-5003
only), or when INPUT2 is selected.
÷
The auto-power-off function can be used only in those cases
other than the inputs used in the preceding item.
÷
Always turn off the plasma display
s main power switch when
not using the display for extended periods of time.
INPUT
MENU
SET
2
/
3
1
Press the MENU button to display the menu screen.
MENU
INPUT1
PICTURE
SCREEN
SETUP
OPTION
:
0
:
0
:
0
:
0
:
0
:
0
CONTRAST
:
0
BRIGHTNESS
R.LEVEL
G.LEVEL
B.LEVEL
H.ENHANCE
V.ENHANCE
PICTURE RESET
2
Use the
2
/
3
buttons to select [SETUP].
[When computer signal is input to INPUT1 or
INPUT5 (PDA-5003 only), or when INPUT2 is used]
:VGA
:
:
SIGNAL FORMAT
CLAMP POSITION
:
AUTO
POWER MANAGEMENT
OFF
MENU
INPUT1
PICTURE
SCREEN
SETUP
OPTION
[In all other cases]
SET
MENU
:
:
DNR
COLOR TEMP.
:
MIDDLE
MIDDLE
:
:
COLOR SYSTEM
PURECINEMA
OFF
AUTO
:
:
CTI
ON
MPEG NR
LOW
AUTO POWER OFF
DISABLE
MENU
INPUT3
PICTURE
SCREEN
SETUP
OPTION
CHANGE
EXIT
3
Press the SET button to confirm selection of the
[POWER MANAGEMENT] or [AUTO POWER OFF].
The factory default setting is [OFF/DISABLE].
Each time the button is pressed, the setting alternates
as follows:
÷
OFF/DISABLE
.....
The display will continue in operating mode,
regardless of the presence/absence of an input sync
signal.
÷
POWER MANAGEMENT: ON
.....
If a sync signal is not detected, a warning message is
first displayed for 8 seconds, after which the display
automatically enters the standby mode, and the ON
indicator flashes green. If a sync signal (*1) is input
again later, the plasma display automatically returns to
normal operating mode.
*1
Except when input signal is G ON SYNC or composite
SYNC.
÷
AUTO POWER OFF: ENABLE
.....
If no sync signal is detected for 8 minutes or more, a
warning message will be displayed for 30 seconds,
after which the display
s power will switch to power off
mode.
4
When the setup is finished, press the MENU
button to exit the menu screen.
Note
The [POWER MANAGEMENT] and [AUTO POWER OFF]
functions must be set individually for each input (INPUT1 to
INPUT5).
To return to operating mode:
÷
To return to normal operation from the [POWER
MANAGEMENT] function
s standby mode, either operate
your computer, or press the
INPUT
button on the plasma
display or remote control unit.
÷
To return to normal operation from the [AUTO POWER
OFF] function
s power off condition, press the
STANDBY/
ON
button on the plasma display or on the remote control
unit.
Operation
MENU
SET
2
/
3
INPUT
Remote control unit
Display operating
panel
3
OFF/DISABLE
ON/ENABLE
2