Poulan PZ4822 User Manual - Page 29
To start an engine with a weak, battery
View all Poulan PZ4822 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 29 highlights
OPERATION To start an engine with a weak battery WARNING! Lead-acid batteries generate explosive gases. Keep sparks, flame and smoking materials away from batteries. Always wear eye protection when around batteries. If your battery is too weak to start the engine, it should be recharged. (See "Battery" in the Maintenance Section. If "jumper cables" are used for emergency starting, follow this procedure: IMPORTANT INFORMATION Your mower is equipped with a 12-volt negative grounded system. The other vehicle must also be a 12-volt negative grounded system. Do not use your mower battery to start other vehicles. To attach jumper cables • Connect each end of the RED cable to the POSITIVE (+) terminal on each battery, taking care not to short against chassis. • Connect one end of the BLACK cable to the NEGATIVE (-) terminal of the fully charged battery. • Connect the other end of the BLACK cable to a good CHASSIS GROUND on the mower with the discharged battery, away from the fuel tank and battery. To remove cables, reverse order • Remove BLACK cable first from chassis and then from the fully charged battery. • Remove RED cable last from both batteries. Jumper cables connection 8011-642 English-28