Rheem 95 Direct Vent Indoor Series Use and Care Manual - Page 13
Horizontal Vent Installation continued.
View all Rheem 95 Direct Vent Indoor Series manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 13 highlights
Installing the water heater: Horizontal Vent Installation continued. Interior Wall 94° Elbow Exterior Wall Wall Plate Determine the heater location and wall construction for correct screw and anchor selection. If mounting on drywall/wallboard it is recommended to locate the wall studs and secure a 1/2 or 3/4" plywood backing plate to the wall studs. Condensate Drain Line Connection Use 4 hollow wall anchors, at least Horizontal Ven1t /8 inch (0.32 cm) in diameter and of Termination appropriate length for the sheathing or Caulk for other composite material. Water Weather Seal Heater Use 4 #10x1-1/4" wood screws for plywood, solid wood sheathing or members. Use suitable masonry anchors for mounting to cement block or solid Mounting Brackets concrete walls. Temporary hang the heater using the Side S VidieeVwiew top mounting screws secured leaving approximately 1/4" (0.64cm) from wall. Determine the vent requirements and the vent exit point and center mark this WARNING: Use Rheem approved Category location. If the heater is below the vent exit remove it from the wall and place it III vent material only. No other vent material is permitted. in a safe area while the vent opening is made. CAUTION: Refer to the vent manufacturer's installation instructions as design might vary from manufacturer to manufacturer. Create a 6" diameter hole to allow the vent to pass without deformation or resistance. Clean debris from the opening and hang the heater and secure all four mounting screws. Dry fit the entire vent system from the heater to the vent termination including the wall plates. Make any corrections if any vent adjustments are required. Disconnect the venting and reassemble according to the vent manufactures recommendations. When fully engaged at the seams the female end will overlap the male end a minimum 1 inch (25.4mm). Use three self tapping screws at each outer pipe seam. Seal each overlapping area of the outer pipe with silicone if required by the vent manufacture. Apply silicone sealant/latex caulk around the vent section where it passes through the wall plate and around the wall plate to keep moisture outside the building. Maintain vent clearances and install vent supports as required by the vent manufacturer. Support method used should maintain clearance and isolate the vent pipe from floor joist or other structural members to help prevent the transmission of noise and vibration. 94° Elbow Fire Stop do1w/4n"wpaerrdfosolotpe Wall Plates Vent Pipe 12" (min) (30 cm) CBeoialirndg Inspection Access Panel #1 (optional) Inspection Access Panel #2 (optional) Example A: Typical Horizontal Termination w/ 1/4" per foot DOWNWARD Slope 13 AP15317 (10_09) DV Gas Manual 10 30 09.indd 13 11/9/2009 3:10:26 PM