Rheem Warrior DVX Series Use and Care Manual - Page 13

Heat Traps, During Installation of this water heater, Insulation Blankets

Page 13 highlights

Installing the water heater. WARNING: If local codes require external application of insulation blanket kits the manufacturer's instructions included with the kit must be carefully followed. Insulation Blankets Insulation blankets, available to the general public, for external use on gas water heaters are not necessary. The purpose of an insulation blanket is to reduce the standby heat loss encountered with storage tank heaters. This water heater meets or exceeds the National Appliance Energy Conservation Act standards with respect to insulation and standby loss requirements making an insulation blanket unnecessary. The manufacturer's warranty does not cover any damage or defect caused by installation, attachment or use of any type of energy saving or other unapproved devices (other than those authorized by the manufacturer) into, onto or in conjunction with the water heater. The use of unauthorized energy saving devices may shorten the life of the water heater and may endanger life and property. The manufacturer disclaims any responsibility for such loss or injury resulting from the use of such unauthorized devices. CAUTION: If local codes require the application of an external insulation blanket to this water heater, pay careful attention to the following so as not to restrict the proper function and operation of the water heater: ● Do not cover the operating or warning labels attached to the water heater or attempt to relocate them on the exterior of insulation blanket. Do not apply insulation to the top of the water heater. This will interfere with the safe operation of the draft hood.  Do not cover the burner access door, jacket door, gas control (thermostat)/gas valve or pressure and temperature relief valve. Heat Traps For increased energy efficiency, some water heaters have been supplied with factory installed 3/4" NPT heat traps in the hot outlet line and cold water inlet line. NOTICE: Do not apply heat to the HOT or COLD water connections. If sweat connections are used, sweat tubing to adapter before fitting adapter to the water connections on heater. Any heat applied to the water supply fittings will permanently damage the dip tube and/or heat traps. During Installation of this water heater........... DO ❑ DO check inlet gas pressure to ensure that it is within the range specified on the rating plate. ❑ DO provide adequate air for combustion and ventilation as discussed in the Use and Care Manual and the National Fuel Gas Code. ❑ DO maintain proper clearances to combustibles as specified on the instruction/ warning label. ❑ DO ensure that the venting system complies with the guidelines found in the Use and Care Manual and National Fuel Gas Code. ❑ DO contact a qualified service technician if the pilot or main burner will not stay lit. DON'T ❑ DON'T block or restrict the vent terminal. ❑ DON'T remove the Burner Access Door unless absolutely necessary. This should only be done by a qualified service technician. A new burner access door gasket must be installed on any burner access door that has been removed. ❑ DON'T install this water heater where standing water may occur. The base of the water heater is meant to be mounted on a dry surface. ❑ DON'T operate the water heater if the sight glass or burner access door grommet is damaged or broken. 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

Installing the water heater.
Heat Traps
For increased energy efficiency, some
water heaters have been supplied with
factory installed 3/4” NPT heat traps
in
the hot outlet line and cold water inlet
line.
NOTICE: Do not apply heat to the
HOT or COLD water connections.
If
sweat connections are used, sweat
tubing to adapter before fitting adapter
to the water connections on heater. Any
heat applied to the water supply fittings
will permanently damage the dip tube
and/or heat traps.
DO
DO
check inlet gas pressure to ensure that
it is within the range specified on the rating
plate.
DO
provide adequate air for combustion
and ventilation as discussed in the Use and
Care Manual and the National Fuel Gas
Code.
DO
maintain proper clearances to
combustibles as specified on the instruction/
warning label.
DO
ensure that the venting system
complies with the guidelines found in the
Use and Care Manual and National Fuel Gas
Code.
DO
contact a qualified service technician
if the pilot or main burner will not stay lit.
DON’T
DON’T
block or restrict the vent
terminal.
DON’T
remove the Burner Access Door
unless absolutely necessary.
This should only
be done by a qualified service technician.
A
new burner access door gasket must be
installed on any burner access door that has
been removed.
DON’T
install this water heater where
standing water may occur.
The base of the
water heater is meant to be mounted on a dry
surface.
DON’T
operate the water heater if the
sight glass or burner access door grommet is
damaged or broken.
During Installation of this water heater
...........
Insulation Blankets
Insulation blankets, available to the
general public, for external use on gas
water heaters are not necessary.
The
purpose of an insulation blanket is to
reduce the standby heat loss encountered
with storage tank heaters.
This water
heater meets or exceeds the
N
ational
Appliance Energy Conservation Act
standards with respect to insulation and
standby loss requirements making an
insulation blanket unnecessary.
The manufacturer’s warranty does not
cover any damage or defect caused by
installation, attachment or use of any type
of energy saving or other unapproved
devices (other than those authorized
by the manufacturer) into, onto or in
conjunction with the water heater. The
use of unauthorized energy saving devices
may shorten the life of the water heater
and may endanger life and property.
The manufacturer disclaims any
responsibility for such loss or injury
resulting from the use of such
unauthorized devices.
CAUTION: If local codes require the
application of an external insulation
blanket to this water heater, pay careful
attention to the following so as not to
restrict the proper function and
operation of the water heater:
Do not cover the operating or warning
labels attached to the water heater or
attempt to relocate them on the exterior
of insulation blanket.
Do not apply insulation to the top of the
water heater. This will interfere with the
safe operation of the draft hood.
Do not cover the burner access door,
jacket door, gas control (thermostat)/gas
valve or pressure and temperature relief
valve.
WARNING: If local
codes require external
application of insulation
blanket kits the
manufacturer’s instructions
included with the kit must
be carefully followed
.
13