colored main burner, pilot burner orifice

Page 26 highlights

Conversion instructions-LP Gas to Natural Gas Slide the notch on the cone onto the flat part of the burner tube, then turn the cone upright and slide the flat end of the burner supply tube into the closed slot. Cone ↶ Burner supply tube Replace red mark colored main burner with (Natural gas) main burner supplied in the package. Reinstall the two #6 screws. Natural/ LowNox Gas Burner LP Burner Red marked color Replace yellow mark pilot burner orifice with the pilot burner natural gas orifice supplied in the bag. Thermocouple Pilot supply tube Burner supply Attach green CAUTION label from the bag to the outside of the water heater near the gas control. Label should be signed by qualified installer or service organization. Return the unused parts to the bag for possible future conversions. Return the bag and this Use and Care manual to the plastic bag attached to the water heater. Reinstall entire burner assembly along with the inner door. Ensure the gasket is fully sealed and the clips are in place. First locate the inner door on the skirt using the tamper proof screws. Now tighten burner supply, pilot tube and thermocouple at the thermostat. DO NOT over-tighten or cross-thread the connections. Reconnect the piezo wire to the piezo ignitor striker. Turn manual gas shut off valve to the ON position and light the water heater as outlined in this manual. Leak test all gas connections and caps with soap/water solution. Bubbles indicate a leak. Make certain all leaks have been repaired, and the inner and outer jacket doors have been replaced. Jacket door Yellow mark indicates LP gas orifice Pilot burner orifice ! WARNING: NEVER use an open flame to test for gas leaks as bodily injury, property damage or death could result. Remove the old inner door gasket. Clean the metal surfaces and replace it with the new gasket provided in the package. 26

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

26
Slide the notch on the cone onto the flat part of the
burner tube, then turn the cone upright and slide the
flat end of the burner supply tube into the closed slot.
Replace
red mark
colored main burner
with (Natural
gas) main burner supplied in the package. Reinstall the
two #6 screws.
Replace
yellow mark
pilot burner orifice
with the
pilot burner natural gas orifice supplied in the bag.
Remove the old inner door gasket.
Clean the metal
surfaces and replace it with the new gasket provided
in the package.
Attach green
CAUTION
label from the bag to the
outside of the water heater near the gas control.
Label
should be signed by qualified installer or service
organization.
Return the unused parts to the bag for possible future
conversions. Return the bag and this Use and Care
manual to the plastic bag attached to the water heater.
Reinstall entire burner assembly along with the inner
door.
Ensure the gasket is fully sealed and the clips
are in place.
First locate the inner door on the skirt
using the tamper proof screws.
Now tighten burner
supply, pilot tube and thermocouple at the thermostat.
DO NOT over-tighten or cross-thread the connections.
Reconnect the piezo wire to the piezo ignitor striker.
Turn manual gas shut off valve to the
ON position and light the water heater as outlined in
this manual. Leak test all gas connections and caps with
soap/water solution. Bubbles indicate a leak. Make
certain all leaks have been repaired, and the inner and
outer jacket doors have been replaced.
!
WARNING: NEVER use an open flame to test for gas leaks as
bodily injury, property damage or death could result.
Natural/ LowNox Gas Burner
LP Burner
Red
marked
color
Pilot supply
tube
Burner supply
Thermocouple
Yellow mark
indicates LP
gas orifice
Pilot burner orifice
Jacket door
Cone
Burner supply tube
↶
Conversion instructions—LP Gas to Natural Gas