Samsung DV363EWBEUF/A1 Trouble Shooting Guide User Manual Ver.1.0 (English, Fr - Page 9
Gas Model, Warning - dryer model
View all Samsung DV363EWBEUF/A1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 9 highlights
TROUBLE SHOOTING WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. GAS MODEL Radiant Sensor(10RS) Resistance value < 1 ٠If resistance is infinite, replace Radiant sensor Gas Valve(25M01A) Valve 1-2 : Resistance value 1.2K ٠Valve 1-3 : Resistance value 0.5K ٠Valve 4-5 : Resistance value 1.2K ٠If resistance is infinity, replace Valve Igniter(101D) Resistance value 40~400 ٠If resistance is infinite, replace Igniter Thermostat (60T21 Hi-Limit)230F-50F Resistance value < 1 ٠If resistance is infinity, replace Thermostat 9 Technical_information-02365J_EN.indd 9 2012-06-05 �� 5:08:15
9
GAS MODEL
TROUBLE SHOOTING
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before
servicing, unless testing requires power.
Radiant Sensor(10RS)
Resistance value < 1 Ω
If resistance is infinite, replace Radiant sensor
Igniter(101D)
Resistance value 40~400 Ω
If resistance is infinite, replace Igniter
Gas Valve(25M01A)
Valve 1-2 : Resistance value 1.2K Ω
Valve 1-3 : Resistance value 0.5K Ω
Valve 4-5 : Resistance value 1.2K Ω
If resistance is infinity, replace Valve
Thermostat (60T21 Hi-Limit)230F-50F
Resistance value < 1 Ω
If resistance is infinity, replace Thermostat
Technical_information-02365J_EN.indd
9
2012-06-05
�� 5:08:15