Samsung NA30R5310FS/AA Installation Guide - Page 23

Supplied parts, English 23, NA30*5310F, Orifice markings

Page 23 highlights

Supplied parts The following parts make up the LP conversion kit: NA30*5310F* NA36*5310F* The all orifices' positions are marked on the provided sheet. The spud in the pressure regulator is factory-installed for Natural Gas (NG) use. LP conversion requires spud removal and reinstallation for LP use. BURNER ORIFICE SIZES AND OUTPUT RATINGS (LP Gas [Propane] 10 in WCP) Burner Location BTU Rate Orifice size [mm] RF ¹ 12500 1.06 RF ² 11500 1.04 LF ¹ 11500 1.04 LF ² 8000 0.83 RR 4500 0.62 LR 8000 0.83 Center ² 12500 1.06 1 Model NA30*5310F* 2 Model NA36*5310F* Install_NA30R5310FG_AA_DG68-01133A-00_EN.indd 23 BURNER ORIFICE SIZES AND OUTPUT RATINGS (Natural Gas 5 in WCP) Burner Location BTU Rate Orifice size [mm] RF ¹ 17000 1.92 RF ² 13000 1.64 LF ¹ 13000 1.64 LF ² 10000 1.4 RR 5000 1.01 LR 10000 1.4 Center ² 17000 1.92 1 Model NA30*5310F* 2 Model NA36*5310F* NOTE 115 Orifice markings: 115 - Denotes 1.15 mm orifice size opening. English 23 2019-04-12 12:13:38 Installation instructions

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84

English 23
Installation instructions
Supplied parts
The following parts make up the LP conversion kit:
NA30*5310F*
NA36*5310F*
The all orifices’ positions are marked on the provided sheet. The spud in the
pressure regulator is factory-installed for Natural Gas (NG) use. LP conversion
requires spud removal and reinstallation for LP use.
BURNER ORIFICE SIZES AND OUTPUT RATINGS
(LP Gas [Propane] 10 in WCP)
Burner Location
BTU Rate
Orifice size [mm]
RF ¹
12500
1.06
RF ²
11500
1.04
LF ¹
11500
1.04
LF ²
8000
0.83
RR
4500
0.62
LR
8000
0.83
Center ²
12500
1.06
1
Model NA30*5310F*
2
Model NA36*5310F*
BURNER ORIFICE SIZES AND OUTPUT RATINGS
(Natural Gas 5 in WCP)
Burner Location
BTU Rate
Orifice size [mm]
RF ¹
17000
1.92
RF ²
13000
1.64
LF ¹
13000
1.64
LF ²
10000
1.4
RR
5000
1.01
LR
10000
1.4
Center ²
17000
1.92
1
Model NA30*5310F*
2
Model NA36*5310F*
NOTE
115
Orifice markings:
115 – Denotes 1.15 mm orifice size opening.
Install_NA30R5310FG_AA_DG68-01133A-00_EN.indd
23
2019-04-12
°° 12:13:38