When R-Room FANR-FANdoes not operate

Page 61 highlights

Diagnostics 2) When R-Room FAN(R-FAN)does not operate Start Is it during Forced Operation? YES Does Fan operate with DOOR S/W presses?(Including Delay Time) NO Is the R-Room temperature a Fan-On condition? YES Is DOOR S/W normal? YES Is the voltage of MICOM #43 5V (Close condition)? Freezer Door Switch input #43 YES Is insertion of CN71(W/BLUE)of MAIN PCB normal? YES Is voltage of MICOM Pin #30 "HIGH"(5V)? YES Is voltage of IC70 #17 "LOW"(0.7V)? YES Is R-FAN RELAY (SSR72) normal? Check wire assembled status/ Change MAIN PCB AASS'Y 61 NO YES Start Forced Operation Normal R-FAN NO Check temp conditions, Select Super Cool NO Change DOOR S/W NO Check soldering /Change PCB NO Re-insert ConnectorCN71 NO Check soldering /Change PCB NO Check IC70 /Change PCB NO Check RELAY /Change PCB - Reference • Load terminal Measure method.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80

61
Diagnostics
2) When R-Room FAN(R-FAN)does not operate
NO
YES
NO
NO
NO
NO
Start Forced Operation
Is it during
Forced Operation?
Does Fan
operate with DOOR
S/W presses?(Including
Delay Time)
Is the
R-Room temperature a
Fan-On condition?
Is DOOR S/W normal?
Is the
voltage of MICOM #43 5V
(Close condition)?
Is insertion of
CN71(W/BLUE)of MAIN
PCB normal?
Start
YES
Normal R-FAN
Check temp conditions,
Select Super Cool
NO
Change DOOR S/W
YES
Check soldering /Change PCB
YES
Re-insert ConnectorCN71
NO
Is voltage
of MICOM Pin #30
"HIGH"(5V)?
Check soldering /Change PCB
YES
YES
NO
Is voltage
of IC70 #17
“LOW”(0.7V)?
Check IC70 /Change PCB
YES
NO
Is R-FAN RELAY
(SSR72) normal?
Check RELAY /Change PCB
YES
Check wire assembled status/
Change MAIN PCB AASS’Y
Freezer Door Switch input #43
- Reference