Samsung RB215BSSB Service Manual - Page 74
Others Measure Load Terminals, 2 Others Measure Sensor Terminals
View all Samsung RB215BSSB manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 74 highlights
15-2) Others (Measure Sensor Terminals) * Check after disassembling connected to MAIN PCB CN30&CN32 * Because it is NTC TYPE Sensor,risistance decreases as temp increases 1. Measure resistance between CN30 ⑦ and ⑥ for R-Sensor. 2. Measure resistance between CN30 ② and ③ for F-Sensor. 3. Measure resistance between CN30 ⑧ and ⑥ for R Defrost Sensor. 4. Measure resistance between CN30 ⑥ and ④ for F Defrost Sensor. 5. Measure resistance between CN31 ① and ④ for Ambient Sensor. 6. Compare the above values with current temps of Sensor locations (4-6.Temp Sensing Circuit Table)and Part Spec in Manual and evaluate them. 15-3) Others (Measure Load Terminals) NO ITEM SPEC CODE NO 1 PBA MAIN 05 W2 PBA MAIN DA41-00293A 2 PBA PANEL 05 W2 PBA PANEL,BLUE DA41-00264A 115V/60Hz DA26-00022B 3 TRANS DC 220V/50,60Hz 127V/60Hz DA26-00022C DA26-00022D 230V/60Hz DA26-00022E F DEFROST SENSOR DA32-00006C R DEFROST SENSOR DA32-00006C 4 SENSOR F SENSOR DA32-10105S R SENSOR DA32-10105T AMBIENT SENSOR DA32-00011L REMARK - The second part (DA41-XXXXX?)of CODE for MAIN PCB ASS'Y PART may change according to MICOM or Option change,so check it when asking for parts. 74