Samsung RB215BSSB Service Manual - Page 74

Others Measure Load Terminals, 2 Others Measure Sensor Terminals

Page 74 highlights

15-2) Others (Measure Sensor Terminals) * Check after disassembling connected to MAIN PCB CN30&CN32 * Because it is NTC TYPE Sensor,risistance decreases as temp increases 1. Measure resistance between CN30 ⑦ and ⑥ for R-Sensor. 2. Measure resistance between CN30 ② and ③ for F-Sensor. 3. Measure resistance between CN30 ⑧ and ⑥ for R Defrost Sensor. 4. Measure resistance between CN30 ⑥ and ④ for F Defrost Sensor. 5. Measure resistance between CN31 ① and ④ for Ambient Sensor. 6. Compare the above values with current temps of Sensor locations (4-6.Temp Sensing Circuit Table)and Part Spec in Manual and evaluate them. 15-3) Others (Measure Load Terminals) NO ITEM SPEC CODE NO 1 PBA MAIN 05 W2 PBA MAIN DA41-00293A 2 PBA PANEL 05 W2 PBA PANEL,BLUE DA41-00264A 115V/60Hz DA26-00022B 3 TRANS DC 220V/50,60Hz 127V/60Hz DA26-00022C DA26-00022D 230V/60Hz DA26-00022E F DEFROST SENSOR DA32-00006C R DEFROST SENSOR DA32-00006C 4 SENSOR F SENSOR DA32-10105S R SENSOR DA32-10105T AMBIENT SENSOR DA32-00011L REMARK - The second part (DA41-XXXXX?)of CODE for MAIN PCB ASS'Y PART may change according to MICOM or Option change,so check it when asking for parts. 74

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80

74
* Check after disassembling connected to MAIN PCB CN30&CN32
* Because it is NTC TYPE Sensor,risistance decreases as temp increases
1. Measure resistance between CN30
and
for R-Sensor.
2. Measure resistance between CN30
and
for F-Sensor.
3. Measure resistance between CN30
and
for R Defrost Sensor.
4. Measure resistance between CN30
and
for F Defrost Sensor.
5. Measure resistance between CN31
and
for Ambient Sensor.
6. Compare the above values with current temps of Sensor locations
(4-6.Temp Sensing Circuit Table)and Part Spec in Manual and evaluate them.
1
2
3
4
PBA MAIN
PBA PANEL
TRANS DC
SENSOR
05 W2 PBA MAIN
05 W2 PBA PANEL,BLUE
115V/60Hz
220V/50,60Hz
127V/60Hz
230V/60Hz
F DEFROST SENSOR
R DEFROST SENSOR
F SENSOR
R SENSOR
AMBIENT SENSOR
- The second part (DA41-XXXXX?)of CODE for MAIN PCB ASS'Y PART may change according to
MICOM or Option change,so check it when asking for parts.
DA41-00293A
DA41-00264A
DA26-00022B
DA26-00022C
DA26-00022D
DA26-00022E
DA32-00006C
DA32-00006C
DA32-10105S
DA32-10105T
DA32-00011L
NO
ITEM
SPEC
CODE NO
REMARK
15-3) Others (Measure Load Terminals)
15-2) Others (Measure Sensor Terminals)