Sanyo CLM2472 Service Manual - Page 22

Performance Data

Page 22 highlights

5. PERFORMANCE DATA 5-1. Temperature Charts 5-1-1. Temperature Charts (CLM1972) Outdoor Unit CLM1972 Indoor Unit KMS0772 × 1 Cooling Characteristics (RH : 46%, Indoor fan speed : High fan) (230V, 60Hz) (1) Low pressure performance chart 188 (1.3) Lo fan 174 (1.2) 160 (1.1) Hi fan HH fan Indoor air temp. 86°F 80°F 75°F (30°C) (27°C) (24°C) Low pressure at wide tube service valve psig (MPaG) 146 (1.0)77 86 95 104 (25) (30) (35) (40) Outdoor air temperature °F (°C) (2) Operating current performance chart Lo fan 5 Hi fan HH fan Operating current (A) 4 Indoor air temp. 86°F (30°C) 3 8705°°FF((2274°°CC)) 2 77 86 95 104 (25) (30) (35) (40) Outdoor air temperature °F (°C) (3) Indoor discharge air performance chart Indoor discharge air temperature °F (°C) 68.0(20) Lo fan Hi fan HH fan 64.4(18) 60.8(16) 57.2(14) 53.6(12) Indoor air temp. 86°F (30°C) 80°F (27°C) 75°F (24°C) 50.0(10) 46.4( 8) 77 86 95 104 (25) (30) (35) (40) Outdoor air temperature °F (°C) NOTE • This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. • Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) • The performance is for a tubing length of 24.6t (7.5m). If the tubing length is different, the performance chart will vary. 22

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103

Cooling Characteristics
(RH : 46%, Indoor fan speed : High fan)
(230V, 60Hz)
(1) Low pressure performance chart
(2) Operating current performance chart
(3) Indoor discharge air performance chart
This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on
the indoor unit type.
Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value.
(In this case, be sure to stop all the indoor units where performance is not being checked.)
The performance is for a tubing length of 24.6t (7.5m). If the tubing length is different, the performance chart will vary.
NOTE
Low pressure at wide tube service valve
psig (MPaG)
Outdoor air temperature °F (°C)
174
(1.2)
188
(1.3)
160
(1.1)
146
(1.0)
77
(25)
86
(30)
95
(35)
104
(40)
Lo fan
Hi fan
HH fan
Operating current (A)
Outdoor air temperature °F (°C)
4
5
3
2
Lo fan
Hi fan
HH fan
Indoor discharge air temperature °F (°C)
Outdoor air temperature °F (°C)
46.4(
8)
68.0(20)
64.4(18)
60.8(16)
57.2(14)
53.6(12)
50.0(10)
Lo fan
Hi fan
HH fan
Outdoor Unit
CLM1972
Indoor Unit
KMS0772
×
1
5-1-1.
Temperature Charts (CLM1972)
77
(25)
86
(30)
95
(35)
104
(40)
77
(25)
86
(30)
95
(35)
104
(40)
5.
PERFORMANCE DATA
5-1.
Temperature Charts
Indoor air temp. 86°F (30°C)
80°F (27°C)
75°F (24°C)
Indoor air temp. 86°F (30°C)
80°F (27°C)
75°F (24°C)
Indoor air temp. 86°F (30°C)
80°F (27°C)
75°F (24°C)
22