Sanyo CLM2472 Service Manual - Page 54

Trouble Diagnosis of Each Part

Page 54 highlights

8-4. Trouble Diagnosis of Each Part 8-4-1. Problems of Each Part and Inspection Points For details about the inspection points, refer to the Inspection Points for Each Part. Problems Indoor unit Inspection points Outdoor unit Others No. of Inspection Points for Each part Indoor unit Indoor unit does not operate. Operation lamp blinking. Operation lamp does not illuminate. Indoor fan dose not turn. Outdoor unit does not operate. Outdoor fan dose not turn. The compressor (only) does not operate. The compressor stops on occasion. The compressor speed does not increase. The electric expansion valve does not operate. Does not cool or cooling performance is inadequate. Self-Diagnostics check Indoor controller (control unit) Indoor fan motor Room temperature sensor Heat exchanger temperature sensor Inter-unit cable Switch circuit board Outdoor control circuit board (1) Diode module HIC Electrolytic capacitor Fuse (2) Compressor (3) Compressor protective sensor (4) Outdoor fan motor Coil thermistor (5) Electric expansion valve (6) Branch tubing temperature sensor (7) Outdoor unit 54

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103

8-4.
Trouble Diagnosis of Each Part
8-4-1.
Problems of Each Part and Inspection Points
For details about the inspection points, refer to the Inspection Points for Each Part.
Problems
Inspection
points
Indoor unit
Indoor unit does not operate.
Self-Diagnostics check
Indoor controller
(control unit)
Indoor fan motor
Room temperature
sensor
Heat exchanger
temperature sensor
Inter-unit cable
Switch circuit board
Outdoor control circuit
board
Diode module
HIC
Electrolytic capacitor
Fuse
Compressor
Compressor protective
sensor
Outdoor fan motor
Coil thermistor
Electric expansion valve
Branch tubing
temperature sensor
(1)
(2)
(3)
(4)
(5)
(6)
(7)
Operation lamp blinking.
Operation lamp does not illuminate.
Indoor fan dose not turn.
Outdoor unit does not operate.
Outdoor fan dose not turn.
The compressor (only) does not
operate.
The compressor stops on occasion.
The compressor speed does not
increase.
The electric expansion valve does
not operate.
Does not cool or cooling
performance is inadequate.
Outdoor unit
Others
No. of
Inspection
Points for
Each part
Indoor unit
Outdoor unit
54