7. FUNCTIONS 7-1. Explanation of Functions NOTE The numerical values such as temperature, frequency, time and current in parentheses are an example of CM3172 and the values are different from the other models. INITIAL Control/conditions Breaker is ON. The ON/OFF operation button on the remote controller is pressed. Unit operation Explanation Power is supplied to the indoor and outdoor unit control circuits, however the unit remains stopped. Positioning of the outdoor unit electric expansion valve is performed. If automatic operation mode has been selected with the remote controller, operation begins in SENSOR DRY, or COOL mode depending on the room temperature and outdoor temperature at the time operation starts. This applies in the case of automatic COOL operation. Depending on the operational mode, refer to the SENSOR DRY, or COOL item. 42