Sanyo CMH3172 Service Manual - Page 13
Control PCB, External Finish, Heat Exchanger Coil, Compressor, Fan Motor - model
View all Sanyo CMH3172 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 13 highlights
Outdoor Unit CM2472 Control PCB Part No. Controls Control Circuit Fuse Compressor Type Compressor Model / Nominal Output Compressor Oil ... Amount Pints (cc) Coil Resistance (Ambient Temp. 68 °F (20 °C)) Ohm Safety Device CT (Peak current cut-off control) Compressor Discharge Temp. Control Operation cut-off control in abnormal ambient Temp. Overload Relay Model Operation Temp. Run Capacitor Micro F VAC Crankcase Heater Fan Type Q'ty ... Dia. inch (mm) Fan Motor Type Model ... Q'ty No. of Poles Rough Measure RPM (Cool) Nominal Output Coil Resistance (Ambient Temp. 68 °F (20 °C)) W Ohm Safety Device Type Over-Current Protection Over-Heat Protection Run Capacitor Heat Exchanger Coil Coil Rows Fins per inch Face Area External Finish Micro F VAC ft2 (m2) 13 CB-CM2572 Microprocessor 250V 25A DC Twin Rotary (Hermetic) 5KD240XAB21 / 1,700W FV50S ... 1.91 (900) U - V : 0.720 V - W : 0.708 W - U : 0.726 Yes Yes Yes CS-7LN115 Open : 239 °F (115 °C), Close : 212 °F (100 °C) - Propeller 1 ... D18-1/8 (D460) DC Motor SIC-71FW-D490-1 ... 1 8 750 90 - Internal Controller Yes Yes - Aluminum Plate Fin / Copper Tube 2 18.1 6.40 (0.595) Acrylic baked-on enamel finish DATA SUBJECT TO CHANGE WITHOUT NOTICE.