2. SPECIFICATIONS 2-1. Unit Specifications Outdoor Unit CM1972 Indoor Unit KMS0972 × 3 Type Number of Connectable Indoor Units Number of Operatable Indoor Units Voltage Rating Performance Electrical Rating Total Capacity Sensible Capacity Latent Capacity Air Circulation (High) Available Voltage Range Running Amperes Power Input Power Factor EER SEER Compressor Locked Rotor Amperes Fuse or Circuit Breaker Capacity BTU/h kW BTU/h BTU/h ft3/min (m3/h) V A W % BTU/h/W BTU/Wh A A Features Control Fan Speeds Compressor Refrigerant / Amount charged at shipment Refrigerant Control Operation Sound (High) Cool Refrigerant Tubing Connections Max. allowable tubing length per unit Refrigerant Narrow tube Tube Diameter Wide tube Ibs (g) dB-A ft (m) inch (mm) inch (mm) Dimensions & Weight Unit Dimensions Height × Width × Depth Package Dimensions Height × Width × Depth Weight Net Shipping Shipping Volume inch (mm) inch (mm) Ibs (kg) Ibs (kg) cu.ft (m3) < 230V > 3-Room Multi Outdoor Unit 3 3 230V Single-Phase 60Hz Cooling 19,700 ( 9,800 to 19,700 ) 5.80 ( 2.90 to 5.80 ) 16,800 2,900 1,707 (2,900) 187 to 253 7.0 1,570 98 12.5 16.5 13.0 20 Outdoor Unit Microprocessor Auto (Hi, Me, Lo) DC Twin Rotary (Inverter) R410A / 6.17 (2,800) Electric Expansion Valve 50 Flare Type 82 (25) 1/4 (6.35) × 3 3/8 (9.52) × 3 Outdoor Unit 29-1/8 × 35-7/16 × 12-19/32 (740 × 900 × 320) 33-27/32 × 40-5/8 × 16-1/4 (860 × 1,032 × 413) 138.9 (63.0) 147.7 (67.0) 12.71 (0.36) DATA SUBJECT TO CHANGE WITHOUT NOTICE. Remarks: 1. The values shown in performance section and electrical rating section above are based on the following unit combination. For other combination unit, please refer to the "Unit Combination Tables" in this manual. Indoor Unit : KMS0972 3units Outdoor Unit : CM1972 1unit 2. Rating conditions are: Cooling : Indoor air temp. 80°F D.B./ 67°F W.B. Outdoor air temp. 95°F D.B./ 75°F W.B. 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99

2.
SPECIFICATIONS
2-1.
Unit Specifications
Outdoor Unit
CM1972
Indoor Unit
KMS0972
×
3
Remarks:
1.
The values shown in performance section and electrical rating section above are based on the following unit combination.
For other combination unit, please refer to the "Unit Combination Tables" in this manual.
Indoor Unit : KMS0972
3units
Outdoor Unit : CM1972
1unit
2.
Rating conditions are:
Cooling :
Indoor air temp.
80°F D.B./ 67°F W.B.
Outdoor air temp.
95°F D.B./ 75°F W.B.
< 230V >
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Compressor
Refrigerant / Amount charged at shipment
Ibs (g)
Refrigerant Control
7.0
1,570
19,700
5.80
( 9,800 to 19,700 )
( 2.90 to 5.80 )
Shipping Volume
Cooling
16,800
2,900
Net
Shipping
Package Dimensions
Weight
Height
×
Width
×
Depth
Height
×
Width
×
Depth
Ibs (kg)
Ibs (kg)
cu.ft (m
3
)
(mm)
inch
(mm)
3-Room Multi Outdoor Unit
Outdoor Unit
inch
187 to 253
Dimensions & Weight
Refrigerant Tubing Connections
Unit Dimensions
Electrical Rating
Sensible Capacity
Latent Capacity
W
Power Input
V
A
Available Voltage Range
Running Amperes
Operation Sound (High) Cool
Narrow tube
Wide tube
Refrigerant
inch (mm)
Tube Diameter
inch (mm)
138.9
147.7
12.71
(63.0)
(67.0)
(0.36)
33-27/32
×
40-5/8
×
16-1/4
(860
×
1,032
×
413)
(740
×
900
×
320)
Outdoor Unit
29-1/8
×
35-7/16
×
12-19/32
1/4 (6.35)
×
3
3/8 (9.52)
×
3
ft (m)
dB-A
Max. allowable tubing length per unit
Flare Type
82 (25)
R410A / 6.17 (2,800)
Electric Expansion Valve
DC Twin Rotary (Inverter)
Fan Speeds
Auto (Hi, Me, Lo)
Control
Microprocessor
Features
Compressor Locked Rotor Amperes
50
BTU/h
Performance
%
Power Factor
98
A
13.0
Type
BTU/h
kW
Total Capacity
BTU/h
SEER
BTU/Wh
16.5
3
Number of Connectable Indoor Units
3
Number of Operatable Indoor Units
230V Single-Phase 60Hz
Voltage Rating
1,707 (2,900)
Air Circulation
(High)
ft
3
/min (m
3
/h)
EER
BTU/h/W
12.5
Fuse or Circuit Breaker Capacity
A
20
6