Sanyo PLC-XF47 Owners Manual - Page 78
Status Read Command, CR' [Command] 'CR
UPC - 086483068959
View all Sanyo PLC-XF47 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 78 highlights
Appendix Status Read Command Format The command is sent from PC to the projector with the format below; 'CR' [Command] 'CR' Command: one character (refer to the command table below. The projector decodes the command and returns the 'Charactor string' with the format below; Command CR0 CR6 Function Status Read Temperature Read Projector Return 00 80 40 20 10 28 02 24 04 21 81 88 S1 S2 S3 Projector status Power On Stand-by mode Countdown Cooling down Power Malfunction Cooling down at the temperature anomaly Unable to receive the RC232C command. Cooling down at Power Management mode Power Management mode after Cooling down Cooling down after the projector is turned off when the lamps are out. Stand-by mode after Cooling down when the lamps are out. Stand-by mode after Cooling down at the temperature anomaly. S1 = Temperature at Sensor 1 (˚C) S2 = Temperature at Sensor 2 (˚C) S3 = Temperature at Sensor 3 (˚C) (ex.) S1 = 12.3˚C, S2 = 23.4˚C, S3 = 34.5˚C --> The projector displays "12.3 23.4 34.5" (F or each sensor, two digit and the tenth place numbers are displayed with a space between each temperature.) ? Communication failure The tables on page 77 and 78 show the typical command lists for controlling the projector. Please consult your local dealer for further information of other commands. 78