Schwinn 490 Elliptical Service Manual - Page 55
The Console display shows the START TEST SUITE
View all Schwinn 490 Elliptical manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 55 highlights
10. The Console display shows the System Units prompt with the current setting. Tap the Programs button 4 times to advance through the System Menu. 11. The Console display shows the Hardware Variant & Console Firmware Version. The sample screen shows the format (values may be different). Push and hold for 3 seconds the Resistance Level Quick 25 button to go to the Manufacturing Test Menu. 12. The Console display shows the START TEST SUITE menu option. Push the Resistance Down () button 2 times to advance to the AUTO CAL_RESISTANCE (Automated Calibrate Resistance) option. If the Start button was pushed instead of the Resistance Down () button twice, turn the Power Switch to OFF and return to Step 1. When the display shows "CALIBRATE RESISTANCE" do NOT push Start. This option is not used. Push the Resistance Down () button one more time. If the Resistance Down () button was pushed more than 2 times going past the AUTO CAL_RESISTANCE option, push the Resistance Increase () button to return to the AUTO CAL_RESISTANCE (Automated Calibrate Resistance) option. 13. The Console display shows the AUTO CAL_RESISTANCE (Automated Calibrate Resistance) option. Push the Start button. Note: If the Pause/Stop button is pushed part way through the calibration (exit), the new calibration is not saved. 14. The console will display changing text and numbers for approximately 30 seconds as the servo motor moves. 55