Sennheiser SK 300 G3 Instructions for Use - Page 22
Transmission situation, Sensitivity setting, Frequency, Channels, frequencies are factory
View all Sennheiser SK 300 G3 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 22 highlights
Adjusting settings via the operating menu The following figures are a guide to the best settings: Transmission situation Loud music/vocals Presentations Sensitivity setting −30 to −21 dB −21 to 0 dB Selecting the frequency bank and the channel manually - "Frequency Preset" Menu Frequency Preset B.Ch: 1. 1 Call up "Frequency Preset" Frequency Preset B.Ch: 1. 1 518.200 MHz Select the frequency bank and confirm Frequency Preset B.Ch: 20. 1 531.375 MHz Select the channel; store the setting "Stored" When you are in the "Frequency Preset" menu item, the RF signal is deactivated. Overview of the frequency banks and channels: Frequency bank Channels Type "1" to "20" up to 24 per System bank: frequency frequencies are factory- bank preset "U1" to "U6" up to 24 per User bank: frequency frequencies are freely bank selectable When setting up multi-channel systems, please observe the following: Only the factory-preset frequencies within one frequency bank are intermodulation-free (see page 27). Bodypack transmitter and receiver of a transmission link have to be set to the same frequency. ̈ It is vital to observe the notes on frequency selection on page 27. Entering a name - "Name" Menu Name Lichael Call up "Name" Name Lichael Enter a character and confirm Name Michael Enter a character; store the setting "Stored" Via the "Name" menu, you can enter a freely selectable name (e.g. the name of the performer) for the bodypack transmitter. 21