Sharp AF-R100CX AF-R100CX , AF-R120CX , AF-R140CX Operation Manual - Page 13

Energy Saver, To Change Air Flow Direction, Exhaust

Page 13 highlights

HOW TO OPERATE ENERGY SAVER During normal operation, the thermostat automatically controls cooling and the fan runs continuously. When the ENERGY SAVER is selected, the thermostat automatically controls cooling and the fan automatically stops when the compressor is not operating. (Fan will stop 30 seconds after the compressor stops.Even after the fan stops, the fan will rotate for 2 minutes, every maximum 20 minutes, to detect room temperature.) Procedure Pad Display / Indicator During cooling operation 1 Touch ENERGY SAVER pad. ENERGY SAVER • ENERGY SAVER indicator will light. 2 To cancel, touch ENERGY SAVER pad again. ENERGY SAVER • ENERGY SAVER indicator will go off. NOTE: ENERGY SAVER cannot be set during FAN ONLY mode operation. TO CHANGE AIR FLOW DIRECTION Adjust the louvers to change the direction of air flow for uniform and efficient cooling of the room. Horizontal louvers Adjusts UP/DOWN air flow Vertical louvers Adjusts LEFT/RIGHT air flow EXHAUST If air in your room is stale, set the EXHAUST lever to the OPEN position. This will exhaust stale air to the outside. The EXHAUST lever should normally be kept in the CLOSED position during cooling for maximum efficiency. CLOSED EXHAUST Lever OPEN 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

13
CLOSED
OPEN
EXHAUST Lever
ENERGY
SAVER
ENERGY
SAVER
HOW TO OPERATE
ENERGY SAVER
TO CHANGE AIR FLOW DIRECTION
During normal operation, the thermostat automatically controls cooling and the fan runs
continuously. When the ENERGY SAVER is selected, the thermostat automatically
controls cooling and the fan automatically stops when the compressor is not operating.
(Fan will stop 30 seconds
after the compressor stops.
Even after the fan stops, the fan will
rotate for 2 minutes, every maximum 20 minutes, to detect room temperature.
)
Procedure
Pad
2
To cancel, touch
ENERGY SAVER
pad again.
ENERGY SAVER indicator
will light.
ENERGY SAVER
indicator
will go off.
NOTE:
ENERGY SAVER cannot be set during FAN ONLY mode operation.
Display / Indicator
During cooling operation
1
Touch ENERGY
SAVER
pad.
Adjust the louvers to change the direction
of air flow for uniform and efficient cooling
of the room.
Vertical louvers
Adjusts LEFT/RIGHT air flow
If air in your room is stale, set the
EXHAUST lever to the OPEN position.
This will exhaust
stale air to the outside.
The EXHAUST lever should normally
be kept in the CLOSED position
during
cooling for maximum efficiency.
EXHAUST
Horizontal louvers
Adjusts UP/DOWN air flow