Sharp AF-R100CX AF-R100CX , AF-R120CX , AF-R140CX Operation Manual - Page 6
Warning, Caution
View all Sharp AF-R100CX manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 6 highlights
INSTALLATION INSTRUCTIONS 2 (1) Unscrew the 2 screws at the corners of the front panel. Keep them as they will be used later. (2)Remove the front panel by pulling the front panel at the lower corners towards you about an inch. Front panel Next lift it up and pull it towards you. CAUTION: Take care not to damage the exhaust lever when removing the front panel. Horizontal Louver Front panel Exhaust Lever 3 (1)Unscrew the 6 stopper screws of the cabinet. Keep the 4 screws from the top and front , as they will be used later. (2)Slide the chassis out from the cabinet by pulling on the hand hold located at the bottom center of the chassis. CAUTION: Do not remove any material (ex. styrofoam, etc.) from inside the unit. 4 Insert the right closure assembly and the left closure assembly into the top angle and the bottom channels. Secure the right and left closure to the cabinet with 6 of the provided screws. (L=13 / 32", 10 mm) Closure assembly 5 Open the window sash and place the cabinet on the sill. Close the window sash securely behind the top angle. If there is space between the bottom channel and the sill, fill the gap with a thin board or other hard filler. WARNING At this step, make sure the cabinet is inclined approximately 1 cm (3/8") to the back. If the cabinet is not properly inclined, the water collected in the bottom tray during operation will not drain properly and may flow into the room where the air conditioner is installed. 6 Cabinet sill incline backwards about 1cm (3/8")