Sharp AF-S125EX AF-R100EX , AF-R120EX Operation Manual

Sharp AF-S125EX Manual

Sharp AF-S125EX manual content summary:

  • Sharp AF-S125EX | AF-R100EX , AF-R120EX Operation Manual - Page 1
    ROOM AIR CONDITIONER INSTALLATION AND OPERATION MANUAL AF-S100EX AF-S120EX AF-S125EX AF-R100EX AF-R120EX This INSTALLATION AND OPERATION MANUAL explains the proper use of your new Sharp Air Conditioner. Read these instructions carefully before installing or operating your air conditioner. The
  • Sharp AF-S125EX | AF-R100EX , AF-R120EX Operation Manual - Page 2
    PARTS (for your Authorized Parts Distributor) ACCESSORIES ADDITIONAL CUSTOMER INFORMATION TO WRITE: For service problems, warranty information, missing items and other assistance: Sharp Electronics Corporation Customer Assistance Center 1300 Naperville Drive Romeoville, IL 60446-1091 Please provide
  • Sharp AF-S125EX | AF-R100EX , AF-R120EX Operation Manual - Page 3
    ): Where to Obtain Service: What to Do to Obtain Service: AF- S100EX, AF-S120EX, AF-S125EX, AF-R100EX or AF-R120EX Room Air Conditioner Sharp Authorized Servicer, call Sharp Toll Free at 1-800-BE-SHARP. Contact your Sharp Authorized Servicer to obtain in-home service for this Product. The Servicer
  • Sharp AF-S125EX | AF-R100EX , AF-R120EX Operation Manual - Page 4
    Before beginning installation, read these instructions carefully. Use the enclosed MOUNTING KIT for proper installation. CHECK WINDOW AREA The mounting kit is designed for wooden sill double or single hung sash-
  • Sharp AF-S125EX | AF-R100EX , AF-R120EX Operation Manual - Page 5
    INSTALLATION INSTRUCTIONS ITEMS PACKED WITH THIS UNIT No. Accessories Q'ty 1 Right closure assembly 1 2 Left closure assembly 1 ! 3 Window sash foam seal 1 Window sash foam seal 4 (adhesive type) 1 " 5 Top
  • Sharp AF-S125EX | AF-R100EX , AF-R120EX Operation Manual - Page 6
    INSTALLATION INSTRUCTIONS 3 (1)Unscrew the 5 stopper screws of the cabinet. Keep the 3 screws from the front and side, as they will be used later. (2)Slide the chassis out
  • Sharp AF-S125EX | AF-R100EX , AF-R120EX Operation Manual - Page 7
    INSTALLATION INSTRUCTIONS 8 Insert the closure assemblies on both sides into the rails of the jamb. Closure assembly (Left) Jamb (Left) Indoor side 1/2 inch (13mm) Sill Stool 9 (1) Secure
  • Sharp AF-S125EX | AF-R100EX , AF-R120EX Operation Manual - Page 8
    FOR USE IMPORTANT: Points to keep in mind when using your air conditioner. • Install the air conditioner by following the installation instructions given in the previous section of this manual. • Make sure the unit is the correct capacity for the area you want to cool. • Do not modify any part
  • Sharp AF-S125EX | AF-R100EX , AF-R120EX Operation Manual - Page 9
    PRECAUTIONS NOTES ON OPERATION • Allow 3 minutes for the compressor to restart cooling. If you turn the air conditioner off and immediately restart it, allow three minutes for the compressor to restart cooling. There is an electronic device in the unit that keeps the compressor off three minutes for
  • Sharp AF-S125EX | AF-R100EX , AF-R120EX Operation Manual - Page 10
    HOW TO OPERATE PARTS NAMES UNIT 5 67 4 8 9 10 3 11 12 2 1 1 Front panel 2 Air inlet (Indoor side) 3 Vertical louvers 4 Horizontal louvers 5 Air outlet (Indoor side) 6 Exhaust lever 7 Control panel 13 8 Cabinet 9 Air outlet (Outdoor side) 10 Air inlet (Outdoor side) 11 Filter handle 12
  • Sharp AF-S125EX | AF-R100EX , AF-R120EX Operation Manual - Page 11
    HOW TO OPERATE COOLING OPERATION COOL indicator POWER indicator F hr SLEEP COOL TEMP SELECTOR TIMER ON/OFF ENERGY POWER SAVER ON/OFF POWER ON/OFF pad 1 Touch POWER ON/OFF pad. • The unit is preset at 74°F and HIGH COOL. This will show in the display when the power is first turned on. •
  • Sharp AF-S125EX | AF-R100EX , AF-R120EX Operation Manual - Page 12
    HOW TO OPERATE TO CHANGE TEMPERATURE SETTING F hr SLEEP COOL TEMP SELECTOR TIMER ON/OFF ENERGY POWER SAVER ON/OFF TEMPERATURE setting pad During cooling operation Touch the TEMPERATURE setting pad to adjust the temperature setting. ---Lower temp. ---Raise temp. • Temperature can be set
  • Sharp AF-S125EX | AF-R100EX , AF-R120EX Operation Manual - Page 13
    HOW TO OPERATE ENERGY SAVER OPERATION During normal operation, the thermostat automatically controls cooling and the fan runs continuously. When the ENERGY SAVER OPERATION is selected, the thermostat automatically controls cooling and the fan automatically stops when the compressor is not operating
  • Sharp AF-S125EX | AF-R100EX , AF-R120EX Operation Manual - Page 14
    HOW TO OPERATE ON TIMER OPERATION • This unit has a built-in timer that can be programmed to start the unit up to 12 hours in advance. You can set the timer to start in increments of 30 minutes (0.5 hours) up to 9.5 hours in advance of the start time, or in 1 hour increments from 10 to 12 hours in
  • Sharp AF-S125EX | AF-R100EX , AF-R120EX Operation Manual - Page 15
    HOW TO OPERATE OFF TIMER OPERATION • This unit has a built-in timer that can be programmed to shut the unit off up to 12 hours in advance. You can set the timer to stop in increments of 30 minutes (0.5 hours) up to 9.5 hours in advance of the stop time, or in 1 hour increments from 10 to 12 hours
  • Sharp AF-S125EX | AF-R100EX , AF-R120EX Operation Manual - Page 16
    HOW TO OPERATE USING THE REMOTE CONTROL INSTALLING BATTERIES Use two size-AA (R6) batteries. 1 Open the battery compartment cover. 2 Insert and slide the batteries into the compartment, making sure the and polarities are properly aligned. 3 Close the cover. Battery compartment cover NOTES: • The
  • Sharp AF-S125EX | AF-R100EX , AF-R120EX Operation Manual - Page 17
    HOW TO OPERATE OPERATING WITH THE REMOTE CONTROL TRANSMITTER POWER ON / OFF TEMP. SELECTOR OFF TIMER SLEEP POWER ON/OFF button Push to start or stop the operation. TEMP. button TEMP. ---Raise temp. setting 1°F at a time. TEMP. ---Lower temp. setting 1°F at a time. SELECTOR button Push to change
  • Sharp AF-S125EX | AF-R100EX , AF-R120EX Operation Manual - Page 18
    CENLEARNGIYNGEFAFNICDIEMNACINYTTEIPNSANCE CLEANING THE FILTER If the filter is clogged with dust, the amount of air flow will be reduced, resulting in poor cooling performance. The filter should be cleaned every10 days. At the beginning of every cooling season or after a long period of inactivity,
  • Sharp AF-S125EX | AF-R100EX , AF-R120EX Operation Manual - Page 19
    BEFORE CALLING FOR SERVlCE IF YOUR AIR CONDITIONER DOES NOT OPERATE PROPERLY, PLEASE CHECK THE FOLLOWING ITEMS BEFORE CALLING FOR SERVICE. AIR CONDITIONER DOES NOT OPERATE AT ALL • Is the unit plugged in or is the plug loose? • Is the fuse blown or the circuit breaker
  • Sharp AF-S125EX | AF-R100EX , AF-R120EX Operation Manual - Page 20
    SHARP ELECTRONICS CORPORATION Sharp Plaza, Mahwah, New Jersey 07430-2135 SHARP CORPORATION Osaka, Japan Printed in Thailand TINSEA362JBRZ 03MO TH 1 20
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

ROOM AIR CONDITIONER
INSTALLATION AND OPERATION
MANUAL
PAGE
CONTENTS
This INSTALLATION AND OPERATION
MANUAL explains the proper use of your
new
Sharp Air Conditioner. Read these instructions
carefully before installing
or operating
your air
conditioner. The INSTALLATION
AND
OP-
ERATION
MANUAL
should be kept in a safe
place for handy reference.
FOR YOUR PROTECTION
....................
2
CONSUMER LIMITED WARRANTY
.....
3
INSTALLATION INSTRUCTIONS
• CHECK WINDOW AREA
........................
4
• LOCATlON
..............................................
4
• ITEMS PACKED WITH THlS UNIT
.........
5
• SUGGESTED TOOLS
............................
5
• INSTALLATION
.......................................
5
PRECAUTIONS
CAUTION FOR USE
............................
8
• GROUNDING INSTRUCTIONS
...........
8
• NOTES ON OPERATION
....................
9
• ENERGY EFFICIENCY TIPS
...............
9
HOW TO OPERATE
• PARTS NAMES
...................................
10
COOLING OPERATION
......................
11
• TO CHANGE FAN SPEED AND
OPERATION MODE
.......
11
TO CHANGE TEMPERATURE SETTING
..........
12
TO CHANGE AIR FLOW DIRECTION
.......
12
• EXHAUST
............................................
12
• ENERGY SAVER OPERATION
...........
13
• SLEEP OPERATION
...........................
13
• ON TIMER OPERATION
.....................
14
• OFF TIMER OPERATION
....................
15
• USING THE REMOTE CONTROL
.......
16
CLEANING AND MAINTENANCE
........
18
BEFORE CALLING FOR SERVlCE
......
19
AF-S100EX
AF-S120EX
AF-S125EX
AF-R100EX
AF-R120EX
As an ENERGY STAR Partner, Sharp Electronics has determined that these products (AF-S100EX, AF-
S120EX, AF-S125EX) meet the ENERGY STAR guidelines for energy efficient air conditioners.
To meet
these guidelines, air conditioners must be at least 10% more efficient than the minimum Federal standard.