ON TIMER OPERATION, Touch the TIMER ON/OFF pad to set the, delayed start time.
View all Sharp AF-S125EX manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 14 highlights
HOW TO OPERATE ON TIMER OPERATION • This unit has a built-in timer that can be programmed to start the unit up to 12 hours in advance. You can set the timer to start in increments of 30 minutes (0.5 hours) up to 9.5 hours in advance of the start time, or in 1 hour increments from 10 to 12 hours in advance of the start time. • The unit will start automatically according to your setting. COOL indicator F hr SLEEP COOL TEMP SELECTOR TIMER ON/OFF ENERGY POWER SAVER ON/OFF TIMER ON/OFF pad TIMER indicator (If you wish to start the operation 6 hours and 30 minutes later, set the delay time as shown above.) When the unit is not operating 1 Touch the TIMER ON/OFF pad to set the delayed start time. • The time setting will change as you touch the pad. The display will change as follows; Preset(0.5h) Previous setting 0.5h 1.0h 1.5h 10h CL(cancel) 12h 11h • The timer will be set, 5 seconds after the TIMER ON/OFF pad is touched for the last time. • TIMER indicator will light. • Cool indicator will light when cooling operation is selected. • The time display will count down the remain- ing time. • The unit will start when the set time expires. The temperature setting will be displayed. TO CANCEL THE TIMER SETTING Touch the TIMER ON/OFF pad again after the timer is set, or press the TIMER ON/OFF pad until CL(cancel) appears on the display. 14