Sharp AF-S125EX AF-R100EX , AF-R120EX Operation Manual - Page 11
Cooling Operation, To Change Fan Speed And Operation Mode, Touch Power On/off Pad.
View all Sharp AF-S125EX manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 11 highlights
HOW TO OPERATE COOLING OPERATION COOL indicator POWER indicator F hr SLEEP COOL TEMP SELECTOR TIMER ON/OFF ENERGY POWER SAVER ON/OFF POWER ON/OFF pad 1 Touch POWER ON/OFF pad. • The unit is preset at 74°F and HIGH COOL. This will show in the display when the power is first turned on. • POWER indicator and COOL indicator will light. 2 To turn off the unit, touch POWER ON/OFF pad again. • POWER indicator and COOL indicator will go off. TO CHANGE FAN SPEED AND OPERATION MODE COOL indicator F hr SLEEP COOL TEMP SELECTOR TIMER ENERGY POWER ON/OFF SAVER ON/OFF SELECTOR pad During operation Touch SELECTOR pad and select the operation mode and fan speed. • Fan speed and operation mode will change as you touch. HIGH COOL MED COOL LOW COOL LOW FAN MED FAN HIGH FAN NOTES ON OPERATION MODE: MODE COOL indicator HIGH COOL light on MED COOL light on LOW COOL light on HIGH FAN light off MED FAN light off LOW FAN light off DISPLAY Cooling operation with high fan speed. Cooling operation with medium fan speed. Cooling operation with low fan speed. Fan only operation with high fan speed. Fan only operation with medium fan speed. Fan only operation with low fan speed. • When the SELECTOR is changed to fan only operation from cooling operation, it will take 5 seconds for the compressor to stop. 11