Sharp AR-M350 AR-M280 AR-M350 AR-M450 Operation Manual (for facsimile) - Page 74

When A Transaction Report Is Printed - service mode

Page 74 highlights

WHEN A TRANSACTION REPORT IS PRINTED The machine has been set to automatically print a Transaction Report when a transmission is not successful or when the Broadcast transmission function is used. The Transaction Report informs you of the result of the operation. When the machine prints a Transaction Report, be sure to check the contents. The initial settings (factory settings) for printing Transaction Reports are indicated by shading below. You can use the key operator program to change the settings (page 8-5). • Single sending: Print out all report / Print out error report only / No printed report • Receiving: Print out all report / Print out error report only / No printed report • Broadcasting: Print out all report / Print out error report only / No printed report • Confidential reception: Print out notice page / Not print out notice page The Transaction Report shows the date of transmission, the time transmission began, the other party's name, the duration of the operation, the number of pages, and the result. NOTES • The list count appears in the "#" column of the Transaction Report and a serial number appears in the FILE column. (These numbers are not related to the transaction.) • When a transmission error occurs, a portion of the original document is printed along with the Transaction Report. You can set the machine to not print the original using the key operator program (page 8-5). s Information appearing in the TYPE/NOTE column Information such as the type of transmission and type of error appears in the TYPE/NOTE column of the Transaction Report. The following notes may appear. Note OK G3 ECM SG3 FW. NO RESPONSE BUSY CANCEL P. FAIL MEMORY OVER MEM. FULL LENGTH OVER ORIGINAL ERROR PASS# NG NO RX POLL RX POLL FAIL NO F-CODE POLL RX POLL# NG F PASS# NG BOX NO. NG F POLL PASS# NG RX NO F-CODE POLL NO F FUNC NO F-CODE M. BOX: [xxxxxx FAIL xx(xxxx) Explanation The transaction was completed normally. Communication took place in G3 mode. Communication took place in G3 ECM mode. Communication took place in Super G3 mode. The received data was forwarded. No response from the receiving party. Transmission was not possible because the other party was already using the line. A transmission was canceled while in progress, or a stored transmission job was canceled. A power failure occurred during the transaction. The memory became full during quick on-line transmission. The memory became full during reception. The transmitted document was over 59" long and therefore could not be received. Manual transmission was not successful because a jam occurred. The connection was broken because the polling passcode was not correct. The machine that was polled does not have a polling function. The other machine refused the polling operation, or your machine broke the connection when polled because no data was in memory. The other machine refused an F-code polling operation, or your machine broke the connection when polled because no data was in its F-code memory polling box. Your machine broke the connection because the other machine specified an F-code polling sub-address that does not exist in your machine. Your machine broke the connection because the other machine sent an incorrect passcode for F-code polling. Your machine broke the connection because the specified sub-address for an F-code memory box does not exist. Your machine broke the connection because an incorrect passcode was sent for an F-code transmission. F-code polling was attempted, however, the other machine did not have an F-code polling memory box. F-code transmission was attempted, however, the other machine does not support F-code communication. An F-code transmission was refused by the other machine because of an incorrect sub-address or other reason. Data was received to a confidential or relay broadcast memory box, or data was sent from a memory polling box. The name of the memory box appears in [xxxxxx], and the type of F-code operation (relay request reception, polling memory transmission, or confidential reception) appears in The communication handshake signals or image signals were distorted due to line conditions or other reasons, and communication was not successful. First two digits of communication error number: Error code from 00 to 31 appears. Last four digits of communication error number: Codes for use by service technicians. 7-2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92

7-2
WHEN A TRANSACTION REPORT IS PRINTED
The machine has been set to automatically print a Transaction Report when a transmission is not successful or when
the Broadcast transmission function is used. The Transaction Report informs you of the result of the operation. When
the machine prints a Transaction Report, be sure to check the contents.
The initial settings (factory settings) for printing Transaction Reports are indicated by shading
below. You can
use the key operator program to change the settings (page 8-5).
Single sending: Print out all report / Print out error report only / No printed report
Receiving: Print out all report / Print out error report only / No printed report
Broadcasting: Print out all report / Print out error report only / No printed report
Confidential reception: Print out notice page / Not print out notice page
The Transaction Report shows the date of transmission, the time transmission began, the other party's name, the
duration of the operation, the number of pages, and the result.
NOTES
The list count appears in the "#" column of the Transaction Report and a serial number appears in the FILE column. (These
numbers are not related to the transaction.)
When a transmission error occurs, a portion of the original document is printed along with the Transaction Report. You can
set the machine to not print the original using the key operator program (page 8-5).
Information appearing in the TYPE/NOTE column
Information such as the type of transmission and type of error appears in the TYPE/NOTE column of the Transaction
Report. The following notes may appear.
Note
Explanation
OK
The transaction was completed normally.
G3
Communication took place in G3 mode.
ECM
Communication took place in G3 ECM mode.
SG3
Communication took place in Super G3 mode.
FW.
The received data was forwarded.
NO RESPONSE
No response from the receiving party.
BUSY
Transmission was not possible because the other party was already using the line.
CANCEL
A transmission was canceled while in progress, or a stored transmission job was canceled.
P. FAIL
A power failure occurred during the transaction.
MEMORY OVER
The memory became full during quick on-line transmission.
MEM. FULL
The memory became full during reception.
LENGTH OVER
The transmitted document was over 59" long and therefore could not be received.
ORIGINAL ERROR
Manual transmission was not successful because a jam occurred.
PASS# NG
The connection was broken because the polling passcode was not correct.
NO RX POLL
The machine that was polled does not have a polling function.
RX POLL FAIL
The other machine refused the polling operation, or your machine broke the connection
when polled because no data was in memory.
NO F-CODE POLL
The other machine refused an F-code polling operation, or your machine broke the connection
when polled because no data was in its F-code memory polling box.
RX POLL# NG
Your machine broke the connection because the other machine specified an F-code polling
sub-address that does not exist in your machine.
F PASS#
NG
Your machine broke the connection because the other machine sent an incorrect passcode for F-code polling.
BOX NO. NG
Your machine broke the connection because the specified sub-address for an F-code memory box does not exist.
F POLL PASS# NG
Your machine broke the connection because an incorrect passcode was sent for an F-code transmission.
RX NO F-CODE POLL
F-code polling was attempted, however, the other machine did not have an F-code polling memory box.
NO F FUNC
F-code transmission was attempted, however, the other machine does not support F-code communication.
NO F-CODE
An F-code transmission was refused by the other machine because of an incorrect sub-address or other reason.
M. BOX: [xxxxxx]
Data was received to a confidential or relay broadcast memory box, or data was sent from a
••••••
memory polling box.
The name of the memory box appears in [xxxxxx], and the type of F-code operation (relay
request reception, polling memory transmission, or confidential reception) appears in
••••••
.
FAIL xx(xxxx)
The communication handshake signals or image signals were distorted due to line conditions
or other reasons, and communication was not successful.
First two digits of communication error number: Error code from 00 to 31 appears.
Last four digits of communication error number: Codes for use by service technicians.