Sharp R-1500 R-1500 , R-1501 , R-1502 Microwave Operation Manual - Page 32

Specifications, Service Call Check - dimensions

Page 32 highlights

SERVICE CALL CHECK Please check the following before calling for service: Place one cup of water in a glass measuring cup in the oven and close the door securely. Operate the oven for one minute at HIGH 100%. A Does the oven light come on? YES _______ NO _______ B Does the cooling fan work? (Put your hand over the left side of louver.) C Does the turntable rotate? (It is normal for the turntable to turn in either direction.) YES _______ NO _______ YES _______ NO _______ D Is the water in the oven warm? YES _______ NO _______ If "NO" is the answer to any of the above questions, please check electrical outlet, fuse and/or circuit breaker. If they are functioning properly, CONTACT YOUR NEAREST SHARP AUTHORIZED SERVICER. A microwave oven should never be serviced by a "do-it-yourself" repair person. NOTE: If time appearing in the display is counting down very rapidly, check Demonstration Mode on page 29 and cancel. SPECIFICATIONS AC Line Voltage: AC Power Required: Output Power: Frequency: Outside Dimensions: Cavity Dimensions: Oven Capacity: Cooking Uniformity: Weight: R-1500, R-1501, R-1502, R-1505, R-1506 Single phase 120V, 60Hz, AC only 1640 watts, 14.0 amps. 1000 watts* (IEC Test Procedure) 2450 MHz 29 15/16"(W) x 16 1/4"(H) x 15 9/16"(D) 17 1/2"(W) x 9 7/8"(H) x 14 15/16"(D) 1.5 Cu. Ft. Turntable system Approx. 55 lb 5 The International Electrotechnical Commission's standardized method for measuring output wattage. This test method is widely recognized. In compliance with standards set by: FCC - Federal Communications Commission Authorized. DHHS - Complies with Department of Health and Human Services (DHHS) rule, CFR, Title 21, Chapter I, Subchapter J. - This symbol on the nameplate means the product is listed by Underwriters Laboratories, Inc. 32

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

32
R-1500, R-1501, R-1502, R-1505, R-1506
SPECIFICATIONS
The International Electrotechnical Commission’s standardized method for measuring output wattage. This
test method is widely recognized.
In compliance with standards set by:
FCC
Federal Communications Commission Authorized.
DHHS
Complies with Department of Health and Human Services (DHHS) rule, CFR, Title 21, Chapter I,
Subchapter J.
This symbol on the nameplate means the product is listed by Underwriters Laboratories, Inc.
AC Line Voltage:
AC Power Required:
Output Power:
Frequency:
Outside Dimensions:
Cavity Dimensions:
Oven Capacity:
Cooking Uniformity:
Weight:
Single phase 120V, 60Hz, AC only
1640 watts, 14.0 amps.
1000 watts* (IEC Test Procedure)
2450 MHz
29
15
/
16
"(W) x 16
1
/
4
"(H) x 15
9
/
16
"(D)
17
1
/
2
"(W) x 9
7
/
8
"(H) x 14
15
/
16
"(D)
1.5 Cu. Ft.
Turntable system
Approx. 55 lb
Please check the following before calling for service:
Place one cup of water in a glass measuring cup in the oven and close the door securely.
Operate the oven for one minute at HIGH 100%.
A
Does the oven light come on?
YES
_______
NO _______
B
Does the cooling fan work?
YES
_______
NO _______
(Put your hand over the left side of louver.)
C
Does the turntable rotate?
YES
_______
NO _______
(It is normal for the turntable to turn in either direction.)
D
Is the water in the oven warm?
YES
_______
NO _______
If “NO” is the answer to any of the above questions, please check electrical outlet, fuse and/or circuit
breaker. If they are functioning properly, CONTACT YOUR NEAREST SHARP AUTHORIZED SERVICER.
A microwave oven should never be serviced by a “do-it-yourself” repair person.
NOTE:
If time appearing in the display is counting down very rapidly, check Demonstration Mode on page 29
and cancel.
SERVICE CALL CHECK