Sony SRPX700P Product Manual (SRP-X700P Hardware Operation Manual 1.3) - Page 10

REMOTE PARALLEL Terminal

Page 10 highlights

How to Control the SRP-X700P from External Equipment REMOTE PARALLEL Terminal The REMOTE PARALLEL terminal enables the SRP-X700P to be remotely controlled with a simple circuit connected externally to this terminal. (D-sub 25-pin, female) Terminal shape Recommended cable Cable length : D-sub 25-pin, female : Multi-core shielded cable for data communication : 50 m or less INPUT terminal You can set the functions of the respective terminals from the PARALLEL INPUT FUNCTION setup box in the REMOTE screen of the supplied SRP-X700P Manager software. All faders and sound volume controls can be controlled from a remote location by connecting a variable resistor as shown, in the range of 0 to -∞ dB. You can perform the following operations by adding a make contact. • Input selection of LINE 4 system • Muting • Scene recall • Sound volume adjustment (Up/Down) • Controlling the AV equipment connected to the CONTROL S terminal • Power-ON/STANDBY selection of a projector OUTPUT terminal The turning ON conditions of the respective pins of the OUTPUT terminal can be set from the following. • Input selector state of LINE 4 system • Turning ON the OVER and -∞ indicators • Turning ON the scene recall button • Generation of the Power-ON/STANDBY command of a projector You can select the ON conditions from the PARALLEL OUTPUT FUNCTION setup box on the REMOTE screen of the supplied SRP-X700P Manager software. SRP-X700P Input terminal (No. 2 to No. 13) 0 dB GND (Nos. 1, 14 and 25) -∞ dB 10 kΩ Curve-B variable resistor SRP-X700P Input terminal (No. 2 to No. 13) GND (Nos. 1, 14 and 25) SRP-X700P Output terminal (No. 15 to No. 24) 40 mA MAX N LED 24 V GND MAX (Nos. 1, 14 and 25) Pin No. Function 1 GND 2 INPUT1 3 INPUT2 4 INPUT3 5 INPUT4 6 INPUT5 7 INPUT6 8 INPUT7 9 INPUT8 10 INPUT9 11 INPUT10 12 INPUT11 13 INPUT12 14 GND 15 OUTPUT1 16 OUTPUT2 17 OUTPUT3 18 OUTPUT4 19 OUTPUT5 20 OUTPUT6 21 OUTPUT7 22 OUTPUT8 23 OUTPUT9 24 OUTPUT10 25 GND Notes • Do not apply any reverse voltage across the output terminal. • Do not connect the shield cable of the REMOTE wire and the GND wire to the terminal table or the like. It can cause malfunction and noise. • Install the REMOTE cable away from the dimmer, motor and others. • When the PARALLEL input terminal is used to set the projector power to either the power-ON state or to the power-STANDBY state, the projector power enters the power-ON state when the PARALLEL input is set to ON. The projector power enters the power-STANDBY state when the PARALLEL input is set to OFF. Therefore, use an alternate type switch for power control. 10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

10
REMOTE PARALLEL Terminal
The REMOTE PARALLEL terminal enables the SRP-X700P to be
remotely controlled with a simple circuit connected externally to
this terminal.
Terminal shape
:
D-sub 25-pin, female
Recommended cable
:
Multi-core shielded cable for data
communication
Cable length
:
50 m or less
INPUT terminal
You can set the functions of the respective terminals from the
PARALLEL INPUT FUNCTION setup box in the REMOTE
screen of the supplied SRP-X700P Manager software.
All faders and sound volume controls can be controlled from a
remote location by connecting a variable resistor as shown, in the
range of 0 to
dB.
You can perform the following operations by adding a make contact.
Input selection of LINE 4 system
Muting
Scene recall
Sound volume adjustment (Up/Down)
Controlling the AV equipment connected to the CONTROL S
terminal
Power-ON/STANDBY selection of a projector
OUTPUT terminal
The turning ON conditions of the respective pins of the OUTPUT
terminal can be set from the following.
Input selector state of LINE 4 system
Turning ON the OVER and
indicators
Turning ON the scene recall button
Generation of the Power-ON/STANDBY command of a
projector
You can select the ON conditions from the PARALLEL OUTPUT
FUNCTION setup box on the REMOTE screen of the supplied
SRP-X700P Manager software.
(D-sub 25-pin, female)
<Example of input circuit>
10 k
Curve-B variable
resistor
GND
(Nos. 1, 14 and 25)
<Example of output circuit>
GND
(Nos. 1, 14 and 25)
Pin No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
Function
GND
INPUT1
INPUT2
INPUT3
INPUT4
INPUT5
INPUT6
INPUT7
INPUT8
INPUT9
INPUT10
INPUT11
INPUT12
GND
OUTPUT1
OUTPUT2
OUTPUT3
OUTPUT4
OUTPUT5
OUTPUT6
OUTPUT7
OUTPUT8
OUTPUT9
OUTPUT10
GND
SRP-X700P
SRP-X700P
40 mA MAX
N
SRP-X700P
24 V
MAX
0 dB
dB
Notes
Do not apply any reverse voltage across the output terminal.
Do not connect the shield
cable of the REMOTE wire and the
GND wire to the terminal table or the like. It can cause
malfunction and noise.
Install the REMOTE cable away from the dimmer, motor and
others.
When the PARALLEL input terminal is used to set the projector
power to either the power-ON state or to the power-STANDBY
state, the projector power enters the power-ON state when the
PARALLEL input is set to ON. The projector power enters the
power-STANDBY state when the PARALLEL input is set to
OFF. Therefore, use an alternate type switch for power control.
Input terminal
(No. 2 to No. 13)
Output terminal
(No. 15 to No. 24)
Input terminal
(No. 2 to No. 13)
GND
(Nos.
1,
14 and 25)
How to Control the SRP-X700P from External Equipment
LED