Stihl FS 100 RX Product Instruction Manual - Page 34

Maintenance and Care - valve adjustment

Page 34 highlights

English Maintenance and Care The following intervals apply to normal operating conditions only. If your daily working time is longer or operating conditions are difficult (very dusty work area, etc.), shorten the specified intervals accordingly. Complete machine Visual inspection (condition, leaks) Clean X X X Control handle Check operation X X Air filter Pickup body in fuel tank Clean Replace Have checked by dealer1) Have replaced by dealer1) Fuel tank Clean Carburetor Check idle adjustment - the cutting attachment must not turn X X Readjust idle Spark plug Readjust electrode gap Replace after every 100 operating hours Visual inspection X Cooling inlets Clean Valve clearance Check and, if necessary, have adjusted by dealer after first 139 hours of operation1) Combustion chamber Decoke after first 139 hours of operation, then every 150 hours of operation Check X Spark arresting screen in muffler Clean or replace All accessible screws and nuts (not adjusting screws) Retighten Anti-vibration elements (rubber buffers, Check X springs) Have replaced by dealer1) 32 before starting work after finishing work or daily after each refueling stop weekly monthly every 12 months if problem if damaged if required X X X X X X X X X X X X X X X X X X X X X FS 100 RX

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92

FS 100 RX
English
32
Maintenance and Care
The following intervals apply to normal operating conditions only. If your daily work
-
ing time is longer or operating conditions are difficult (very dusty work area, etc.),
shorten the specified intervals accordingly.
before starting work
after finishing work or daily
after each refueling stop
weekly
monthly
every 12 months
if problem
if damaged
if required
Complete machine
Visual inspection (condition, leaks)
X
X
Clean
X
Control handle
Check operation
X
X
Air filter
Clean
X
X
Replace
X
Pickup body in fuel tank
Have checked by dealer
1)
X
Have replaced by dealer
1)
X
X
X
Fuel tank
Clean
X
X
Carburetor
Check idle adjustment – the cutting
attachment must not turn
X
X
Readjust idle
X
Spark plug
Readjust electrode gap
X
Replace after every 100 operating hours
Cooling inlets
Visual inspection
X
Clean
X
Valve clearance
Check and, if necessary, have adjusted
by dealer after first 139 hours of
operation
1)
X
Combustion chamber
Decoke after first 139 hours of opera
-
tion, then every 150 hours of operation
X
Spark arresting screen in muffler
Check
X
X
Clean or replace
X
X
All accessible screws and nuts (not adjust
-
ing screws)
Retighten
X
Anti-vibration elements (rubber buffers,
springs)
Check
X
X
X
Have replaced by dealer
1)
X