TASCAM CD-A750 RS-232C Specification - Page 23
Rec Mute, Pause, Mecha Status Sense, Media Status Sense, Counter Sense, Counter Reset, Mecha Status
View all TASCAM CD-A750 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 23 highlights
TASCAM CD-A750 RS-232C Protocol Specifications REC MUTE Executes the REC MUTE on cassette deck of the controlled device. Command 1B Machine ID 1 Data none Return none PAUSE Puts the cassette deck of the controlled device in PAUSE mode. Command 1C Machine ID 1 Data none Return none RTZ Executes the RTZ on cassette deck of the controlled device. Command 1D Machine ID 1 Data none Return none MECHA STATUS SENSE Requests that the current mechanism status of the cassette deck of the controlled device be returned. Command 50 Machine ID 1 Data none Return MECHA STATUS RETURN [D0] MEDIA STATUS SENSE Requests that the presence or absence of a media and the type of media be returned. Command 56 Machine ID 1 Data none Return MEDIA STATUS RETURN [D6] COUNTER SENSE Requests that the counter information of the cassette deck of the controlled device be returned. Command 5A Machine ID 1 Data none Return COUNTER RETURN [D6] COUNTER RESET Resets the counter of the cassette deck of the controlled device. Command 65 Machine ID 1 Data none Return none MECHA STATUS RETURN This is the return command for the command "MECHA STATUS SENSE [50]". It returns the current operating status of the mechanism. Command D0 23 TEAC Corporation