Thermador PRG364WLG Installation Instructions - Page 20
Electrical requirements and, connection for DUAL FUEL, models
View all Thermador PRG364WLG manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
Gas unit electrical connection Electrical supply circuit requirements NEMA 5-15 N G NEMA 5-20 N G The cord supplied with the gas ranges having an electric griddle or grill requires a NEMA 5-20 receptacle. All other gas units require a NEMA 5-15 receptacle. Model Voltage Pxx305Wx 120 VAC Pxx366Wx 120 VAC Pxx364WDx 120 VAC Pxx364WLx 120 VAC Pxx486WDx 120 VAC Pxx486WLx 120 VAC Dedicated circuit Phase 15 Amps Single 15 Amps Single 20 Amps Single 20 Amps Single 20 Amps Single 20 Amps Single • Before you plug in an electrical cord, be sure all controls are in the OFF position. • A neutral supply wire must be provided from the power source (breaker) because critical range components, including the surface burner spark reignition modules, require it to operate safely and properly. • All 120 volt models must be plugged into a mating 3prong, grounding-type receptacle. The receptacle must be connected to a properly dedicated grounded and polarized electrical power supply rated at 120VAC, Single Phase, 60Hz. • Observe all governing codes and ordinances when grounding. In the absence of these codes or ordinances observe National Electrical Code ANSI/ NFPA No. 70 current issue, or the relevant Canadian Electric Code, CSA C22.1-02. • Power cord and receptacle should protrude no more than 2" 2'' (51 mm) from the rear wall. (51) NOTE: Plug styles may vary. Electrical requirements and connection for DUAL FUEL models 9 WARNING An improper 240/208 VAC power supply will cause malfunction, damage to this appliance, and possibly create a condition of shock hazard. 9 WARNING This product must be properly grounded. • Before installing, turn power OFF at the service panel. Lock service panel to prevent power from being turned ON accidentally. • Prior to servicing appliance, always disconnect appliance electrical supply cord, if so equipped, from wall receptacle. If appliance is hard-wired to power supply, disconnect power to unit by turning off the proper circuit breaker. Lock service panel to prevent power from being turned ON accidentally. • A neutral supply wire must be provided from the power source (breaker) because critical range components, including the surface burner spark reignition module, require it to operate safely and properly. • Mount the receptacle securely to a wall stud, then seal around the receptacle's housing. 2" (51) max. When using a receptacle it may be necessary to recess the receptacle's housing into the rear wall. Refer to Local Electrical Code to determine the minimum volume for all electrical / junction boxes. Follow all local electrical codes and ordinances, and/or the National Electric Code, as applicable. Volt Circuit 240/208 VAC 50 Amps Frequency Phase 60 Hz. Single Page. 19