Thermador T30IR70NSP Design Guide - Freedom Refrigeration - Page 37

Individual Column Installations, Side-by-side Installations, At The End Of A Kitchen, Individual

Page 37 highlights

FREEDOM® COLLECTION 24-INCH FREEZER COLUMN Models: Flush Column T24ID80NRP, T24ID80NLP, T24IF70NSP INSTALLATION OPTIONS The Freedom® Collection offers you a variety of installation possibilities. In some instances, special accessories are required! INDIvIDUAL COLUMN INSTALLATIONS T24ID80NRP Right-hand door swing T24ID80NLP Left-hand door swing 24-Inch Flush with External Ice and Water Dispenser Build Your Custom Column See pages 230-231 for details. T24IF70NSP 24-Inch Flush, Reversible Door Swing Build Your Custom Column See pages 230-231 for details. SPECIFICATIONS Total Capacity (cu. ft.) Product Width Product Height Product Depth* Cutout Width Cutout Height Cutout Depth** Door Swing Clearance T24ID80NRP T24ID80NLP T24IF70NSP 12.2 23 3/4" 84" 24" 24" 84" 24 3/4" 26 21/32" Door Swing Right Hand Swing, Left Hand Swing Reversible Annual Energy Consumption 505 kWh 446 kWh Electrical Supply Power Cord Included Shipping Weight (lbs.) 120V/15 Amp Circuit 120V-3 prong 375 367 *Depth without door panel **Cutout depth for flush installation with 3/4" thick panel ACCESSORIES See pages 232-233 for Freedom Collection accessories. All refrigerators are UL and CUL approved. 246 SIDE-by-SIDE INSTALLATIONS When two appliances are installed side-by-side, the Sideby-Side Sealing Kit (BSEALKIT10) must be used to ensure a stable connection. When combining two appliances with a freezing function (e.g. two freezers or one bottom mount appliance and one freezer), use the Extreme Combination Side-by-Side Heating Kit (XHEATKIT10). INDIvIDUAL APPLIANCES wITH PARTITION When dimensioning the partition for model 4, note the thickness of the furniture fronts to prevent damage if the doors are opened at the same time. Use the Extreme Combination Side-by-Side Heating Kit (XHEATKIT10) if the gap between the appliance is less than 6" (160 mm) or for permanent connection of two individual appliances, (e.g. freezer or bottom mount appliance next to a freezer). Minimum thickness of the partition 5/8" (16 mm). 1 2 3 4 AT THE END OF A kITCHEN If one side of the appliance is visible, a side panel must be used. The side panel must be connected firmly to the wall, the floor and the overhead furniture/fixtures before the appliance is placed in the cavity. The dimensions of the side panel are taken from the opposite cavity wall. During installation ensure that the cavity is square and the exact size.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50

246
FREEDOM
®
COLLECTION
24-INCH FREEZER COLUMN
Models: Flush Column T24ID80NRP, T24ID80NLP, T24IF70NSP
T24ID80NRP
Right-hand door
swing
T24ID80NLP
Left-hand door
swing
24-Inch Flush
with External
Ice and Water
Dispenser
Build Your
Custom Column
See pages
230-231 for
details.
T24IF70NSP
24-Inch Flush,
Reversible
Door Swing
Build Your
Custom
Column
See pages
230-231 for
details.
ACCESSORIES
See pages 232-233 for Freedom Collection accessories.
INSTALLATION OPTIONS
The Freedom
®
Collection offers you a variety of installation
possibilities. In some instances, special accessories are required!
INDIVIDUAL COLUMN INSTALLATIONS
SIDE-BY-SIDE INSTALLATIONS
When two appliances are installed side-by-side, the Side-
by-Side Sealing Kit (BSEALKIT10) must be used to ensure a
stable connection.
When combining two appliances with a freezing function
(e.g. two freezers or one bottom mount appliance and one
freezer), use the Extreme Combination Side-by-Side Heating
Kit (XHEATKIT10).
AT THE END OF A KITCHEN
If one side of the appliance is visible, a side panel must be used.
The side panel must be connected firmly to the wall, the floor
and the overhead furniture/fixtures before the appliance is placed
in the cavity.
The dimensions of the side panel are taken from the opposite
cavity wall. During installation ensure that the cavity is square and
the exact size.
INDIVIDUAL APPLIANCES WITH PARTITION
When dimensioning the partition for model 4, note the thickness
of the furniture fronts to prevent damage if the doors are opened
at the same time.
Use the Extreme Combination Side-by-Side Heating Kit
(XHEATKIT10) if the gap between the appliance is less than
6" (160 mm) or for permanent connection of two individual
appliances, (e.g. freezer or bottom mount appliance next to
a freezer).
Minimum thickness of the partition
5
/
8
" (16 mm).
4
2
3
1
All refrigerators are UL and CUL approved.
SPECIFICATIONS
T24ID80NRP
T24ID80NLP
T24IF70NSP
Total Capacity (cu. ft.)
12.2
Product Width
23
3
/
4
"
Product Height
84"
Product Depth*
24"
Cutout Width
24"
Cutout Height
84"
Cutout Depth**
24
3
/
4
"
Door Swing Clearance
26
21
/
32
"
Door Swing
Right Hand
Swing, Left
Hand Swing
Reversible
Annual
Energy
Consumption
505 kWh
446 kWh
Electrical Supply
120V/15 Amp Circuit
Power Cord Included
120V-3 prong
Shipping Weight (lbs.)