Toshiba 61A60 Service Manual - Page 11

ELECTRICAL ADJUSTMENT, Change SCNT data to13H.

Page 11 highlights

GENERAL ADJUSTMENTS SPECIFIC INFORMATIONS ELECTRICAL ADJUSTMENT ITEM VERTICAL POSITION (VCEN) ADJUSTMENT PROCEDURE 1. Call up the adjustment mode display, then select item VCEN. 2. Press the VOLUME s or t button to get the voltage +30 ±10 mV. 3. Measuring method of voltage as follows. TP-V (on SIGNAL board) TP-G (on SIGNAL board) DIGITAL C VOLT METER SUB-BRIGHTNESS (BRTC) SUB-COLOR (SCOL) SUB-TINT (TNTC) SUB-CONTRAST (SCNT) PICTURE POSITION 1. Constrict the picture height until the vertical retrace line appears adjusting the HEIGHT control on the MAIN board. 2. Adjust the CONTRAST to the minimum and BRIGHTNESS to the center. 3. Enter the service mode, then select "BRTC" register. 4. Adjust the data value so the belt of vertical retrace line just disappear. 5. Adjust the HEIGHT control. * Adjust the SUB-BRIGHTENESS after adjusting the WHITE BALANCE. Vertical retrace line 1. Receive color-bar signal from color-bar generator. 2. Adjust the BRIGHTNESS and CONTRAST to the center (RESET status). 3. Connect oscilloscope to TP501on the MAIN board. 4. Enter the service mode, then select "SCOL". 5. Temporarily adjust the data value to achieve about 1V0-p of blue bar. Blue 6. Select "TNTC" register. 7. Adjust the data value to obtain the blue bar to magenta bar ratio of 3:2 as Magenta 3 (1.8V0-P) 2 shown. 0 8. Select "SCOL" register. 9. Adjust the data value to achieve 1.8V0-p of blue bar on scope. 10. Check the picture with off-air signal. 1. Tune in a color program and adjust the BRIGHTNESS and CONTRAST to normal mode(RESET). 2. Enter the service mode, then select "SCNT" register. 3. Change "SCNT" data to13H. 4. Check the picture contrast. 1. Receive the pattern signal which shows it's center on the screen. 2. Adjust the picture position alternately by turning CENTERING MAGNETS for proper picture position. 3. Check the picture with off-air signal. - 11 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50

– 11 –
GENERAL ADJUSTMENTS
ITEM
ADJUSTMENT PROCEDURE
Vertical retrace line
SUB-BRIGHTNESS
(BRTC)
1.
Constrict the picture height until the
vertical retrace line appears adjusting
the HEIGHT control on the MAIN board.
2.
Adjust the CONTRAST to the minimum
and BRIGHTNESS to the center.
3.
Enter the service mode, then select
BRTC
” register.
4.
Adjust the data value so the belt of
vertical retrace line just disappear.
5.
Adjust the HEIGHT control.
* Adjust the SUB-BRIGHTENESS after
adjusting the WHITE BALANCE.
SUB-COLOR
(SCOL)
SUB-TINT
(TNTC)
1.
Receive color-bar signal from color-bar generator.
2.
Adjust the BRIGHTNESS and CONTRAST to the center (RESET status).
3.
Connect oscilloscope to TP501on the MAIN board.
4.
Enter the service mode, then select “
SCOL
”.
5.
Temporarily adjust the data value to
achieve about 1V
0-p
of blue bar.
6.
Select “
TNTC
” register.
7.
Adjust the data value to obtain the blue
bar to magenta bar ratio of 3:2 as
shown.
8.
Select “
SCOL
” register.
9.
Adjust the data value to achieve 1.8V
0-p
of blue bar on scope.
10.
Check the picture with off-air signal.
0
Blue
Magenta
2
3 (1.8V
0-P
)
SUB-CONTRAST
(SCNT)
1.
Tune in a color program and adjust the BRIGHTNESS and CONTRAST to
normal mode(RESET).
2.
Enter the service mode, then select "SCNT" register.
3.
Change "SCNT" data to13H.
4.
Check the picture contrast.
ELECTRICAL
ADJUSTMENT
PICTURE POSITION
1.
Receive the pattern signal which shows it's center
on the screen.
2.
Adjust the picture position alternately by turning
CENTERING MAGNETS for proper picture position.
3.
Check the picture with off-air signal.
VERTICAL POSITION (VCEN)
1.
Call up the adjustment mode display, then select item VCEN.
2.
Press the VOLUME
s
or
t
button to get the voltage +30
±
10 mV.
3.
Measuring method of voltage as follows.
TP-V
TP-G
C
(on SIGNAL board)
(on SIGNAL board)
DIGITAL
VOLT METER