Toshiba S100 PPS10C-LS101E Users Manual Canada; English - Page 210
Comma pause time, DTMF dialing speed, Escape guard time
View all Toshiba S100 PPS10C-LS101E manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 210 highlights
S-registers S8 Comma pause time This register sets the time, in seconds, that the modem must pause when it encounters a comma (,) in the dial command string. In some countries/regions, S8 will set both wait before dialing and comma pause time. Range: 0-255 Default: 2 Units: seconds S11 DTMF dialing speed This register determines the dialing speed which is prefixed for each country/region. Range: 50-255 Default: 95 Units: .001 seconds S12 Escape guard time This register sets the value (in 20 millisecond increments) for the required pause after the escape sequence. Range: 0-255 Default: 50 Units: .02 seconds D-4 User's Manual
D-4
User’s Manual
S-registers
S8
Comma pause time
This register sets the time, in seconds, that the modem must
pause when it encounters a comma (,) in the dial command string.
In some countries/regions, S8 will set both wait before dialing and
comma pause time.
Range:
0-255
Default: 2
Units:
seconds
S11
DTMF dialing speed
This register determines the dialing speed which is prefixed for
each country/region.
Range:
50-255
Default: 95
Units:
.001 seconds
S12
Escape guard time
This register sets the value (in 20 millisecond increments) for the
required pause after the escape sequence.
Range:
0-255
Default: 50
Units:
.02 seconds