Tripp Lite B097048INT Owners Manual for B093- B097- and B098-Series Console Se - Page 140
Send Email, 3.2 Send SMS, 3.3 Perform RPC Action, 3.4 Run Custom Script, 3.5 Send SNMP Trap
View all Tripp Lite B097048INT manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 140 highlights
7. Alerts, Auto-Response and Logging Note: A message text can be sent with Email, SMS and Nagios actions. This configurable message can include selected values: $AR_TRIGGER_VAL = the trigger value for the check e.g. for UPS Status, it could be onbatt or battlow $AR_VAL = the value returned by the check e.g. for ups status, it could be online/onbatt/battlow $AR_CHECK_DEV = the device name of the device being checked e.g. for Alarm, the alarm name $TIMESTAMP = the current timestamp $HOSTNAME = the hostname of the console server The default message text is: $TIMESTAMP: This action was run - Check details: value $AR_VAL vs trigger value $AR_TRIGGER_VAL. 7.3.1 Send Email Click on Send Email as the Add Trigger Action. Enter a unique Action Name and set the Action Delay Time Specify the Recipient Email Address for whom to send this email and the Subject of the email. For multiple recipients, you can enter comma-separated addresses. Edit the Email Text message to send. Click Save New Action. Note: An SMS alert can also be sent via an SMTP (email) gateway. You will need to specify the Recipient Email Address in the format specified by the gateway provider (e.g,. for T-Mobile it is [email protected]). 7.3.2 Send SMS Click on Send SMS as the Add Trigger Action. Enter a unique Action Name and set the Action Delay Time. Specify the Phone number that the SMS will be sent to in international format (without the +). Edit the Message Text to send and click Save New Action. Note: The SMS alert can only be sent if there is an internal cellular modem attached. However, an SMS alert can also be sent via SMTP SMS gateway, as described above. 7.3.3 Perform RPC Action Click on Perform RPC Action as the Add Trigger Action. Enter a unique Action Name and set the Action Delay Time Select a power Outlet and specify the Action to be performed (power ON, OFF or Cycle). Click Save New Action. 7.3.4 Run Custom Script Click on Run Custom Script as the Add Trigger Action. Enter a unique Action Name, and set the Action Delay Time. Create a script file to execute when this action is triggered and enter the Script Executable file name (e.g., /etc/config/ action.sh). Set the Script Timeout (the maximum run-time for the script). Leave as 0 for unlimited. Enter any Arguments that are to be passed to the script and click Save New Action. 7.3.5 Send SNMP Trap Click on Send SNMP Trap as the Add Trigger Action. Enter a unique Action Name, and set the Action Delay Time. Note: SNMP Trap actions are valid for Serial, Environmental, UPS and Cellular data triggers. 140