Tripp Lite SU1500XLCD Owner's Manual for On-Line Tower LCD UPS 933168 - Page 12

Basic Connection and Start-Up

Page 12 highlights

Basic Connection and Start-Up 3 Turn your UPS ON: • Press the "ON" button • Hold it for several seconds until you hear a beep • Release it 3 After successful completion of startup diagnostics, your UPS will turn on into ONLINE MODE. This process takes approximately 20 seconds to complete. The LCD display will flash ON during this 20 seconds. Once the UPS is running in ONLINE MODE, the LCD screen will report output status of ON for about 20 seconds, then switch to begin reporting the last selected status screen.* ONLINE MODE LCD SCREEN (first 20 seconds approx.) after 20 seconds > PLUG icon ON (confirms INPUT POWER status) > BATTERY CHARGE level (5-bar battery charge display) > "ON" refers to OUTPUT status (as indicated by the "OUT" icon) > WAVEFORM icon ON (confirms online-mode operation) > SPEAKER icon (Audible alarm status) * When UPS is first turned-on, it will switch to report input voltage after approximately 20 seconds. If you're having trouble turning the UPS on, you may be pressing the ON button too long. Release the button "during" the beep (not after it stops). Note: UPS system will function properly upon initial startup; however, maximum runtime for the unit's battery will only be accessible after it has been charged for 24 hours. Note: External battery pack options require configuration using the front panel LCD interface or via Tripp Lite's EXTERNAL BATTERY CONFIGURATION software. See page 24 for more information if you are connecting external batteries to one of these UPS models. 12 13-03-138 93-3168-EN.indd 12 3/28/2013 1:05:13 PM

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96

12
Basic Connection and Start-Up
After successful completion of startup diagnostics, your UPS will turn on into ONLINE MODE.
This process takes approximately 20 seconds
to complete.
The LCD display will flash ON during this 20 seconds.
Once the UPS is running in ONLINE MODE, the LCD screen will report
output status of ON for about 20 seconds, then switch to begin reporting the last selected status screen.*
ONLINE MODE LCD SCREEN (first 20 seconds approx.)
* When UPS is first turned-on, it will switch to report input voltage after approximately 20 seconds.
If you're having trouble turning the UPS on, you may be pressing the ON button too long. Release the button "during" the beep
(not after it stops).
Note
: UPS system will function properly upon initial startup; however, maximum runtime for the unit’s battery will only be accessible after it has been charged for 24 hours.
Note
: External battery pack options require configuration using the front panel LCD interface or via Tripp Lite’s EXTERNAL BATTERY CONFIGURATION software. See page 24
for more information if you are connecting external batteries to one of these UPS models.
after 20 seconds
> PLUG icon ON (confirms INPUT POWER status)
> BATTERY CHARGE level (5-bar battery charge display)
> "ON" refers to OUTPUT status (as indicated by the "OUT" icon)
> WAVEFORM icon ON (confirms online-mode operation)
> SPEAKER icon (Audible alarm status)
3
3
Turn your UPS ON:
• Press the “ON” button
• Hold it for several seconds until you hear a beep
• Release it
13-03-138 93-3168-EN.indd
12
3/28/2013
1:05:13 PM