Tripp Lite SU3000RTXL3UHV Owner's Manual for SmartOnline UPS 932609 - Page 11

Condition: No Output due to High

Page 11 highlights

200608121 93-2609 SU Owner's Manual.qxd 10/3/2006 3:32 PM Page 11 Troubleshooting (continued) Lights (On/Flashing) and Condition On: FAULT, BYPASS, LINE, 100%, 75% Condition: On Bypass due to High Internal Temperature Flashing: LINE Condition: Input Abnormal On: FAULT, 100% Flashing: LINE, BYPASS Condition: No Output due to High Output Voltage and Abnormal Input Flashing: LINE, BYPASS On: FAULT, 75% Condition: No Output due to Low Output Voltage and Abnormal Input Flashing: LINE, BYPASS On: FAULT, 50% Condition: No Output due to High Bus Voltage and Abnormal Input Flashing: LINE, BYPASS On: FAULT, 25% Condition: No Output due to Low Bus Voltage and Abnormal Input Flashing: LINE, BYPASS On: FAULT, 100%, 75% Condition: No Output due to High Internal Temperature and Abnormal Input Solution Check the UPS to be sure that there is adequate space for air to circulate near the vents and that the fan is working properly. Restart the UPS. This indicates that utility power is too high or low for the UPS to operate in BYPASS mode, so if an inverter failure occurs, the UPS will deliver no output. Restart the UPS. If the problem persists, contact Tripp Lite for repairs. Restart the UPS. If the problem persists, contact Tripp Lite for repairs. Restart the UPS. If the problem persists, contact Tripp Lite for repairs. Restart the UPS. If the problem persists, contact Tripp Lite for repairs. Check the UPS to be sure that there is adequate space for air to circulate near the vents and that the fan is working properly. Restart the UPS. If the problem persists, contact Tripp Lite for repairs. 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

Troubleshooting
(continued)
Lights (On/Flashing) and Condition
Solution
On: FAULT, BYPASS, LINE, 100%, 75%
Check the UPS to be sure that there is
Condition: On Bypass due to High
adequate space for air to circulate near
Internal Temperature
the vents and that the fan is working
properly. Restart the UPS.
Flashing: LINE
This indicates that utility power is too high
Condition: Input Abnormal
or low for the UPS to operate in BYPASS
mode, so if an inverter failure occurs,
the UPS will deliver no output.
On: FAULT, 100%
Restart the UPS. If the problem persists,
Flashing: LINE, BYPASS
contact Tripp Lite for repairs.
Condition: No Output due to High
Output Voltage and Abnormal Input
Flashing: LINE, BYPASS
Restart the UPS. If the problem persists,
On: FAULT, 75%
contact Tripp Lite for repairs.
Condition: No Output due to Low
Output Voltage and Abnormal Input
Flashing: LINE, BYPASS
Restart the UPS. If the problem persists,
On: FAULT, 50%
contact Tripp Lite for repairs.
Condition: No Output due to High
Bus Voltage and Abnormal Input
Flashing: LINE, BYPASS
Restart the UPS. If the problem persists,
On: FAULT, 25%
contact Tripp Lite for repairs.
Condition: No Output due to Low
Bus Voltage and Abnormal Input
Flashing: LINE, BYPASS
Check the UPS to be sure that there is
On: FAULT, 100%, 75%
adequate space for air to circulate near
Condition: No Output due to High
the vents and that the fan is working
Internal Temperature and Abnormal
properly. Restart the UPS. If the problem
Input
persists, contact Tripp Lite for repairs.
11
200608121 93-2609 SU Owner’s Manual.qxd
10/3/2006
3:32 PM
Page 11