Vantec UGT-ST644R User Guide - Page 16

To manually rebuild a RAID 1 virtual disk, Status, Functional, Degrade

Page 16 highlights

to initiate, resume, or complete the rebuild process. Spare physical disks are not supported. To manually rebuild a RAID 1 virtual disk 1. When a virtual disk is degraded, the Status of a virtual disk is changed from Functional to Degrade, as shown in Figure 11. Figure 11 Virtual Disk Properties: Degrade VD 2. Replace the faulty physical disk with an identical physical disk. Note: If an identical disk is unavailable, use a replacement physical disk or larger size or one with a slightly smaller size as determined the Gigabyte Rounding setting for the virtual disk. The 4 Channel 6-Port SATA 6Gb/s PCIe RAID Host Card detects the new physical disk and lists the device under Free Physical UGT-ST644R Page 16

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

UGT-ST644R
Page 16
to initiate, resume, or complete the rebuild process. Spare physical
disks are not supported.
To manually rebuild a RAID 1 virtual disk
1.
When a virtual disk is degraded, the
Status
of a virtual disk is
changed from
Functional
to
Degrade
, as shown in Figure 11.
Figure 11 Virtual Disk Properties: Degrade VD
2.
Replace the faulty physical disk with an identical physical disk.
Note: If an identical disk is unavailable, use a replacement
physical disk or larger size or one with a slightly smaller size as
determined the Gigabyte Rounding setting for the virtual disk.
The 4 Channel 6-Port SATA 6Gb/s PCIe RAID Host Card detects
the new physical disk and lists the device under Free Physical