ViewSonic CDE9800 User Guide - Page 73

A. Basic Func°on

Page 73 highlights

Get-Function Table A. Basic Function Get Function Length ID Command Command Get-Brightness 8 Get-Backlight*3.2.0 8 Type (ASCII) g a Code (ASCII) b B Code (Hex) 62 42 Get-Volume 8 Get-Mute 8 Get-Input select 8 Get-Power status: 8 ON/ STBY g f 66 g g 67 g j 6A g l 6C Response Range (Three ASCII bytes) 000 ~ 100 000 ~ 100 000 ~ 100 000: Off 001: On (muted) 000~ 100~ 001: ON 000: STBY Comments 1. For Android platform whose main mode is controlled by backlight and the other sources are controlled by bright- ness. 2. Derived from Color calibration. *3.2.0 1.  1st digit for signal detection: 0 means "no signal"; 1 means "signal detected" 2. 2nd &3rd digit: See Set-function table Get-Remote control S Get-Power lock 8 Get-Button lock 8 Get-Menu lock 8 Get-ACK 8 Get-Thermal 8 Get-Operation 8 time*3.2.0 Get-Device name 8 g n 6E 000: Disable Get RCU mode status 001: Enable 002: Pass through g o 6F 000: Unlock 001: Lock g p 70 000: Unlock 001: Lock g l 6C 000: Unlock 001: Lock g z 7A 000 This command is used to test the com- munication link g 0 30 000~100: 0~+100 deg C -01~-99: -1~-99 deg C g 1 31 000 1. Accumulated hours in 6-digit integer (000,001~ 999,999)*3.2.0 2. Can not be reset when FW update and Factory initiation*3.2.2 3. Reply in new 32- byte format*3.2.0 g 4 34 000 Reply in new 32-byte format *3.2.0 73

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96

73
³et-Func°on Oable
A. Basic Func°on
³et Func°on
Length
ID
Command
Command
Response
Range
Comments
Type (ASCII)
Code
(ASCII)
Code
(Hex)
(Three ASCII
bytes)
Get-Brightness
8
g
b
62
000 ~ 100
Get-Backlight
*3.2.0
8
a
B
42
000 ~ 100
1. For Android
platform whose main
mode is controlled
by backlight and the
other sources are
controlled by bright-
ness.
2. Derived from Color
calibration.
*3.2.0
Get-Volume
8
g
f
66
000 ~ 100
Get-Mute
8
g
g
67
000: Off
001: On (muted)
Get-Input select
8
g
j
6A
000~
100~
1. 1st digit for signal
detection: 0 means
“no signal”; 1
means “signal
detected”
2. 2nd &3rd digit: See
Set-function table
Get-Power status:
ON/ STBY
8
g
l
6C
001: ON
000: STBY
Get-Remote control
S
g
n
6E
000: Disable
001: Enable
002: Pass through
Get RCU mode status
Get-Power lock
8
g
o
6F
000: Unlock
001: Lock
Get-Button lock
8
g
p
70
000: Unlock
001: Lock
Get-Menu lock
8
g
l
6C
000: Unlock
001: Lock
Get-ACK
8
g
z
7A
000
This command is
used to test the com-
munication link
Get-Thermal
8
g
0
30
000~100:
0~+100 deg C
-01~-99:
-1~-99 deg C
Get-Operation
time
*3.2.0
8
g
1
31
000
1. Accumulated
hours in 6-digit
integer (000,001~
999,999)
*3.2.0
2. Can not be reset
when FW update and
Factory initiation
*3.2.2
3. Reply in new 32-
byte format
*3.2.0
Get-Device name
8
g
4
34
000
Reply in new 32-byte
format
*3.2.0