PM-FCP Ceiling Anchoring THE PM-FCP MUST SECURED USING THE SUPPLIED QUICK LOCKS AND BRAIDED CABLES. Truss Concrete Wood Truss Loop Braided Cable Concrete Eye Lag Hole Loop Braided Cable Wood Joist Eye Lag Hole Truss ceiling Step 1. Loop the braided cable around the truss. Step 2. Run the open end through the loop. Step 3. Pull the open end down until the braided cable tightens around the truss. Concrete Step 1. Determine the mounting location. Step 2. Use a 1/4" masonry drill bit to pre-drill the mounting holes. Step 3. Place the concrete anchor into the pre-drilled hole and gently tap into place using a rubber mallet or hammer. Wood Joist Step 1. Secure the four (4) ¼" eye lag screws to the wood joist in the ceiling. Step 2. Make sure eye lag screws are properly secured to the joist before securing the wire to the cable locks on the plate. Step 3. Run the open end through the hole in the eye lag screw. Step 4. Run the open end through the loop. Step 5. Pull the open end down until the braided cable tightens around the eye lag screw. Installation Instructions Page 5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

Installation Instructions
Page 5
Ceiling Anchoring
Truss
Concrete
Wood
Truss ceiling
Step 1.
Loop
the
braided
cable
around the truss.
Step 2.
Run the open end through
the loop.
Step 3.
Pull the open end down until
the braided cable tightens
around the truss.
Wood Joist
Step 1.
Secure the four (4) ¼” eye
lag screws to the wood joist
in the ceiling.
Step 2.
Make sure eye lag screws
are properly secured to the
joist before securing the wire
to the cable locks on the
plate.
Step 3.
Run the open end through
the hole in the eye lag
screw.
Step 4.
Run the open end through
the loop.
Step 5.
Pull the open end down until
the braided cable tightens
around the eye lag screw.
Concrete
Step 1
. Determine
the
mounting
location.
Step 2
. Use a 1/4” masonry drill bit
to pre-drill the mounting
holes.
Step 3
. Place the concrete anchor
into the pre-drilled hole and
gently tap into place using a
rubber mallet or hammer.
Truss
Loop
Braided Cable
Loop
Eye Lag Hole
Eye Lag Hole
Concrete
Wood Joist
THE PM-FCP MUST SECURED USING THE SUPPLIED QUICK LOCKS AND BRAID-
ED CABLES.
PM-FCP