Viking MVBI7360W Installation Instructions - Page 17
Leveling Unit, Kickplate Installation
View all Viking MVBI7360W manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 17 highlights
Leveling Unit Once the unit is in position, height adjustment can be made from the front. Remove panel just below the water filter. Using a 5/16" hex drive, turn clockwise to raise the unit or counterclockwise to lower. Use the lowest torque setting when using a power drill. Do not turn the leveling legs by hand. When the unit is properly leveled, door/drawer adjustments are less likely to be necessary. IMPORTANT NOTE: Level the unit to the floor, not surrounding cabinetry. This could affect the operation of the unit, such as door closing. Front Panel B Left Front Adjustment Left Rear A Adjustment Right Rear Adjustment Right Front Adjustment Kickplate Installation After the unit has been adjusted to the proper height, place the kickplate on the lower front with the adjustment screws in the slots. Let the kickplate drop until it hits the floor. Tighten the screws. Adjustment slot Front of unit Adjustment screws kickplate 17